VMAC - Vehicle Mounted Air Compressors
VMAC Technical Support: 888-241-2289
VMAC Knowledge Base: kb.vmacair.com
35
Starting the engine with the recoil starter (pull cord)
The unloader valve should be opened to reduce the load on the
engine during warm up.
Figure 17 — Unloader valve
Figure 16 — Fuel and choke levers
Choke lever
Fuel Lever
Unloader valve
1) If equipped with the optional VMAC Cold Climate kit, ensure the kit is turned off.
2) Close the choke by moving the choke lever all the way to the left (Figure 16).
4) Actuate the unloader valve by pulling out the handle (Figure 17).
The G300004 is designed to operate at an elevated low idle set
point. This is required for optimal engine performance due to
compressor loads. This elevated low idle set point requires the
choke to be applied during both cold and warm starts.
To start the engine (warm or cold), ensure the choke is closed by
confirming that the lever is all the way to the left.
3) Turn on the fuel by moving the fuel shut off lever all the way to the right