Do not disable or bypass any safety components. Disabling or
bypassing safety components could result in equipment damage,
injury or death.
G300004 Safety Components (Figure 7)
•
200 psi pressure relief valve in the separation manifold.
•
Blowdown muffler to discharge system pressure on shut down.
•
Temperature safety switch in compressor.
•
15 A fuse protects the OEM electrical system (located inside the OEM key
start enclosure).
•
15 A fuse protects the fan’s electrical system (located in the wiring harness
next to the starter).
The engine will not be able to be restarted until the system has
cooled and the temperature switch has closed.
Automatic Overheat Shut Down
If the compressor oil temperature exceeds 140 °C (284 °F), the thermostatic switch
will disable the engine. The cooling fan is powered by the battery and will continue
to run as needed to cool the compressor.
Safety Features
200 psi relief
valve
Blowdown
muffler
Figure 7 — Safety components (Shroud removed for clarity)
Temperature
switch