4
-** Limits /
War
n
in
gs
Pa
r.
N
o
. #
P
ar
ameter d
escr
iption
De
fa
u
lt valu
e
4-se
t-u
p
FC 302
on
ly
Ch
an
ge
du
ri
ng
o
p
er
at
io
n
Co
n
ver
-
si
on
index
Typ
e
4
-1* M
o
tor Limit
s
4-
1
0
Mot
o
r Spe
ed
Dire
ction
null
All set-ups
FALSE
-
Uint8
4-
1
1
M
o
to
r Speed
Low Limit [RPM
]
Expre
ssionL
imit
All set-ups
TRUE
67
Uint16
4-
1
2
M
o
to
r Speed
Low Limit [Hz]
Expre
ssionL
imit
All set-ups
TRUE
-1
Uint16
4-
1
3
Mot
o
r Spe
ed
Hi
gh L
im
it
[
R
PM
]
Expre
ssionL
imit
All set-ups
TRUE
67
Uint16
4-
1
4
Mot
o
r Spe
ed
Hi
gh L
im
it
[
H
z]
Expre
ssionL
imit
All set-ups
TRUE
-1
Uint16
4-
1
6
Torqu
e L
imit Motor
Mode
Expre
ssionL
imit
All set-ups
TRUE
-1
Uint16
4-
1
7
T
o
rq
ue
L
imi
t
Ge
ne
ra
to
r M
od
e
1
00.0
%
All set-ups
TRUE
-1
Uint16
4-
1
8
Cu
rre
nt L
im
it
Expre
ssionL
imit
All set-ups
TRUE
-1
Uint32
4-
1
9
Max Out
put Fre
q
ue
ncy
132.
0 Hz
All set-ups
FALSE
-1
Uint16
4
-2* Limit
Factors
4-
2
0
T
o
rq
ue
Li
mi
t F
ac
to
r
S
o
ur
ce
[0] N
o
fu
nction
All set-ups
TRUE
-
Uint8
4-
2
1
Spee
d Lim
it Factor
Sour
ce
[0] N
o
fu
nction
All set-ups
TRUE
-
Uint8
4
-3*
Mo
tor Fb Monitor
4-
3
0
Mot
o
r Fee
dba
ck Loss Func
tion
[2
] T
ri
p
All set-ups
TRUE
-
Uint8
4-
3
1
Mot
o
r Fee
dba
ck Spe
ed Err
o
r
300 RP
M
All set-ups
TRUE
67
Uint16
4-
3
2
Mot
o
r Fee
dba
ck Loss Tim
eou
t
0.0
5
s
All set-ups
TRUE
-2
Uint16
4
-5* Adj. Warning
s
4-
5
0
Wa
rn
in
g C
u
rr
en
t
Low
0
.00 A
All set-ups
TRUE
-2
Uint32
4-
5
1
War
n
ing C
u
rr
en
t
High
Im
axVLT (P1637
)
All set-ups
TRUE
-2
Uint32
4-
5
2
War
n
ing Sp
ee
d Low
0 RP
M
All set-ups
TRUE
67
Uint16
4-
5
3
War
n
ing Sp
ee
d High
outpu
tSpee
dHighLimit (
P
413)
All set-ups
TRUE
67
Uint16
4-
5
4
W
ar
n
ing Reference
Lo
w
-9999
99.9
99 N/A
All set-ups
TRUE
-3
Int32
4-
5
5
W
ar
n
ing Reference High
9
99999.
999 N
/A
All set-ups
TRUE
-3
Int32
4-
5
6
War
n
ing Fe
ed
back
Lo
w
-999999
.999
Ref
erenceFe
edbac
kU
n
it
All set-ups
TRUE
-3
Int32
4-
5
7
War
n
ing Fe
ed
back High
999
999.
999 Re
fere
n
ce
Fee
dbackUnit
All set-ups
TRUE
-3
Int32
4-
5
8
Mi
ssi
n
g
Mot
o
r P
h
as
e Fu
nct
ion
[1] On
All set-ups
TRUE
-
Uint8
4
-6* Speed
Bypass
4-
6
0
Bypass Spe
ed
From
[RPM]
Expre
ssionL
imit
All set-ups
TRUE
67
Uint16
4-
6
1
Bypass Spe
ed
From
[Hz]
Expre
ssionL
imit
All set-ups
TRUE
-1
Uint16
4-
6
2
Bypass Spe
ed
to [RPM]
Expre
ssionL
imit
All set-ups
TRUE
67
Uint16
4-
6
3
Bypass Spe
ed
To [H
z]
Expre
ssionL
imit
All set-ups
TRUE
-1
Uint16
VLT
®
AutomationDrive FC 300 Instruction Manual
How
to
Program
52
MG.33.A8.22 - VLT
®
is a registered Danfoss trademark.