1283 Power EEPROM data version mismatch
1284 Cannot read Digital Signal Processor
software version
1299 Option SW in slot A is too old.
1300 Option SW in slot B is too old.
1301 Option SW in slot C0 is too old.
1302 Option SW in slot C1 is too old.
1315 Option SW in slot A is not supported (not
allowed).
1316 Option SW in slot B is not supported (not
allowed).
1317 Option SW in slot C0 is not supported
(not allowed).
1318 Option SW in slot C1 is not supported
(not allowed).
1536 An exception in the Application Orienta-
ted Control is registered. Debug infor-
mation written in LCP
1792 DSP watchdog is active. Debugging of
power part data Motor Orientated Con-
trol data not transferred correctly
2049 Power data restarted
2315 Missing SW version from power unit
2816 Stack overflow Control board module
2817 Scheduler slow tasks
2818 Fast tasks
2819 Parameter thread
2820 LCP stack overflow
2821 Serial port overflow
2822 USB port overflow
3072-5
122
Parameter value is outside its limits.
Perform an initialization. Parameter
number causing the alarm: Subtract the
code from 3072. Ex Error code 3238:
3238-3072 = 166 is outside the limit
5123 Option in slot A: Hardware incompatible
with Control board hardware
5124 Option in slot B: Hardware incompatible
with Control board hardware
5125 Option in slot C0: Hardware incompati-
ble with Control board hardware
5126 Option in slot C1: Hardware incompati-
ble with Control board hardware
5376-6
231
Out of memory
WARNING 40
Overload of Digital Output Terminal 27:
Check the load connected to terminal 27 or re-
move short-circuit connection. Check parameters
5-00 and 5-01.
WARNING 41
Overload of Digital Output Terminal 29:
Check the load connected to terminal 29 or re-
move short-circuit connection. Check parameters
5-00 and 5-02.
WARNING 42
Overload of Digital Output On X30/6 :
Check the load connected to X30/6 or remove
short-circuit connection. Check parameter 5-32.
WARNING 42
Overload of Digital Output On X30/7 :
Check the load connected to X30/7 or remove
short-circuit connection. Check parameter 5-33.
WARNING 47
24 V supply low:
The external 24 V DC backup power supply may
be overloaded, otherwise contact your Danfoss
supplier.
WARNING 48
1.8 V supply low:
Contact your Danfoss supplier.
WARNING 49
Speed limit:
The speed is not within the range specified in par.
4-11 and par. 4-13.
ALARM 50
AMA calibration failed:
Contact your Danfoss supplier.
ALARM 51
AMA check Unom and Inom:
The setting of motor voltage, motor current, and
motor power is presumably wrong. Check the set-
tings.
ALARM 52
AMA low Inom:
The motor current is too low. Check the settings.
ALARM 53
AMA motor too big:
The motor is too big for the AMA to be carried out.
VLT
®