2.5.2 Concentric Vertical Flue Systems
The vertical flue kit (optional extra) with extensions may be used to provide a straight
length of up to10 m (393 in) and include two 87° elbows or three 45° elbows.
An extra 87° elbow can be used but this reduces the maximum permissible length by 1 m
(40 in). An extra 45° elbow can be used but this reduces the maximum permissible length
by 0.5 m (20 in).
Refer to figure 2/A to determine which option kits are required before commencing the
installation. Installation instructions for installing the appliance with a standard flue and
straight extension ducts are included in the main text of these instructions.
Figure 2/A shows the optional flue systems available for use with the Vitodens 200.
2 Technical Specifications
7
CONCENTRIC HORIZONTAL
CONCENTRIC VERTICAL