4 Installation Procedure
a)
Refer to Figure 4/I. Note that the flue can be installed prior to the boiler (if
desired) because the flue support bracket supplied as an optional extra will
hold the flue system in place. Install the flue system as follows:
Step 1: Push the adaptor into the top half of the spigot at the top of the boiler as shown
Step 2: If applicable, push any extension ducts into the elbow.
Step 3: Push the roof sealing assembly over the flue terminal and slide the flue terminal
assembly through the roof from outside the building. Push the terminal into the adaptor
(or extension duct).
Step 4: Make good the roof seal from outside the building.
4.8.2 Vertical Flue Systems
Figure 4/I:
Installing a vertical flue system
2
1
3
4
31