6 Routine Servicing
6.4 Combustion Chamber Cleaning
6.5 Air Pressure Switch Sensing Pipes
a)
If required, clean combustion chamber (A) and heating surfaces within with a
soft brush, or flush with water. Important. Scratches on parts which are in
contact with flue gases can lead to corrosion. Only use plastic brushes rather
than wire brushes.
b)
Replace the burner assembly as a reverse of removal.
a)
Check that the pressure switch sensing pipes are not blocked or damaged. It
is not necessary to remove the air pressure switch; this is not adjustable and
does not require any servicing.