a)
Gain access by following step 9.1(b).
b)
Locate the limit thermostats (Figure 9/A). Disconnect the electrical connections
to the faulty thermostat.
c)
Unscrew the two screws securing the faulty thermostat to the flow pipe and
remove the thermostat.
d)
Fit the new thermostat (using heat sink compound supplied with the new
thermostat) and reassemble in reverse order.
e)
Finally, ensure that the outer casing is secured in position and carry out an
ignition check.
9 Replacement of Parts
9.11 DHW Thermistor (A) (Combi only)
9.10 Limit Thermostat
59