2.5.1 Concentric Horizontal Flue Systems
Standard horizontal flue kit: The appliance is supplied complete with a standard concentric
horizontal balanced flue terminal assembly suitable for flue lengths of up to 620 mm (24.4 in)
from the centre of the flue outlet which equates to wall thicknesses of up to 380 mm (15 in) for
rear flues or 370 mm (14.6 in) for side flues with minimum clearances.
Extension ducts can be used to increase the straight flue length up to 10 m (393 in) and include
two 87° elbows or three 45°elbows. An extra 87° elbow can be used but this reduces the
maximum permissible length by 1m (40 in). An extra 45° elbow can be used but this reduces the
maximum permissible length by 0.5 m (20 in).
Right hand side
10mm (3/8in)
10mm (3/8in)
Left hand side
10mm (3/8in)
10mm (3/8in)
Top (above casing)
350mm (14in)
350mm (14in)
Front
450mm (18in)
450mm (18in)
The following minimum clearances must be maintained for installing and servicing the appliance.
Connection Sizes
Combi
System
Gas
Rc 1/2 (Female)
Rc 1/2 (Female
Central heating flow
Rc 3/4 (Female)
Rc 3/4 (Female)
Central heating return
Rc 3/4 (Female)
Rc 3/4 (Female)
Domestic water inlet
Rc 1/2 (Female)
_
Domestic water outlet
Rc 1/2 (Female)
_
Pressure relief valve outlet
Rc 3/4 (Female)
Rc 3/4 (Female)
Condensate connection
19mm (Female) Flexible
19mm (Female) Flexible
2 Technical Specifications
2.4 Minimum Installation Clearances
2.5 Flue System Specifications