Figure 3/B: Typical System Design (Combi Boiler)
Note: The boiler incorporates an internal bypass to ensure adequate water flow, however one radiator
(preferably in the bathroom) should be permanently open (fitted with two lockshield valves) to dissipate any
excess heat.
•
The following Viessmann control
configurations are available:-
Constant Temperature = Compatible
Timer with Constant Temperature = Compatible
Weather Compensated Controls = Compatible
UTD = Compatible
The Boiler will require a permanent live feed via plug 40. (see section 4)
Detailed recommendations for air supply are given in BS 5440:2. The following
notes are for general guidance.
a)
It is not necessary to have a purpose provided air vent in the room or
internal space in which the appliance is installed.
b)
If the boiler is to be installed in a cupboard or compartment, no permanent
air vents are required for cooling purposes in the cupboard or
compartment, however, it is essential to ensure that the minimum
clearances stated in section 2.4 are maintained.
3 Installation Requirements
3.4 Ventilation Requirements
14