background image

  

 

INSTRUCTION MANUAL 

 

THE MONTAGUE COMPANY 

1830 Stearman Avenue  P.O. BOX 4954 

HAYWARD,CA 94540-4954 

TEL: 510/785-8822  FAX: 510/785-3342                

                     

Heavy Duty

 

Underfired Gas Broilers 

M

ONTAGUE

 

Radiant Models: 

Range Match

: UF (-24R, -30R, -36R, -48R, -60R, -72R) 

Freestanding

: UFS (-24R, -30R, -36R, -48R, -60R, -72R)    

Low-Profile Counter

: UFLC (-24R, -30R, -36R, -48R, -60R, -72R)  

Modular

: UFSM (-24R, -30R, -36R, -48R, -60R, -72R) 

Counter:

 UFSC (-24R, -30R, -36R, -48R, -60R, -72R) 

Shallow Counter:

 UFLCS (-24R, -30R, -36R, -48R, -60R, -72R) 

 

 

 

Keep area around appliances free and clear from combustibles. 

PLEASE RETAIN THIS MANUAL  

FOR FUTURE REFERENCE. 

These instructions should be read thoroughly before attempting installation. 

Set up and installation should be performed by qualified installation personnel. 

Summary of Contents for Legend series

Page 1: ...0R 36R 48R 60R 72R Low Profile Counter UFLC 24R 30R 36R 48R 60R 72R Modular UFSM 24R 30R 36R 48R 60R 72R Counter UFSC 24R 30R 36R 48R 60R 72R Shallow Counter UFLCS 24R 30R 36R 48R 60R 72R Keep area around appliances free and clear from combustibles PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE These instructions should be read thoroughly before attempting installation Set up and installation shou...

Page 2: ...nt of damage 3 CONCEALED LOSS OR DAMAGE If damage is unnoticed until merchandise is un packed notify transportation company or carrier immediately and file concealed dam age claim with them This should be done within fifteen 15 days of date that delivery was made to you Be sure to retain container for inspection We cannot assume responsibility for damage incurred in transit We will however be glad...

Page 3: ...mplied with all requirements of state and local authorities having jurisdiction Reference National Electric Code N F P A No 70 latest addenda THE INSTALLATION INSTRUCTIONS CONTAINED HEREIN ARE FOR THE USE OF QUALIFIED INSTALLATION AND SERVICE PERSONNEL ONLY INSTALLATION OR SERVICE BY OTHER THAN QUALIFIED PERSONNEL MAY RESULT IN DAMAGE TO THE OVEN INJURY TO THE OPERATOR READ CAREFULLY AND FOLLOW TH...

Page 4: ...h burner performance or may extinguish the pilot flame In case of unsat isfactory oven performance re check performance with the exhaust fan turned OFF Clearances Adequate clearance must be provided in the aisle and at the side and back to allow the doors to open sufficiently to permit the removal of the racks and for serviceability Adequate clearance for air openings into the combustion chamber m...

Page 5: ...the legs Battery Arrangements 1 Place the first unit in the exact position it will occupy in the battery 2 Using a carpenter s level level the unit from front to rear and side to side Adjust as follows FLOOR INSTALLATION ON LEGS Adjust by turning foot on adjustable legs CURB INSTALLATION Place shim under the low side This operation is important since variations in floors and curbs are common Unles...

Page 6: ...for the manifold pressure marked on the rating plate 3 4 REAR MANIFOLD The gas pressure regulator supplied with this unit must be used FOR NATURAL GAS the gas pressure regulator is factory adjusted for 6 0 WC manifold pres sure The maximum inlet pressure to the regulator should not exceed 10 5 WC FOR PROPANE GAS the gas pressure regulator is factory adjusted for 10 0 WC manifold pres sure The maxi...

Page 7: ...er from underneath Replace screen 2 Set pilot valve with screwdriver to provide 1 2 flame by turning counterclockwise 3 Turn desired burner valve on 4 To shutdown turn pilot valve clockwise until tight 5 Do not attempt to relight for 5 minutes after shutdown The burner flame should be 1 1 2 to 2 high on natural gas and approximately 3 4 to 1 on pro pane gas Turn the gas valve on and off several ti...

Page 8: ...y them before returning to the broiler BURNERS Under normal use burners should not require cleaning but periodic inspection for heat deterioration is recommended GREASE CONTAINERS Each unit contains at least one grease container to catch grease in the far left hand corner of the broiler and at least one large tray to catch drippings from the broiler The large tray should be removed every couple of...

Page 9: ...AME WHILE THE BROILER IS OPERATING OR STILL HOT LOWER WARMING RACK US UFS UFSC UFSM Models Simply pull out to load and push in to warm Uses the radiant heat from above for added versatility from your MONTAGUE underfired broiler Not recommended for direct cooking on the rack Products are exposed to falling debris from grid above and probably will require covering Cooking The MONTAGUE Heavy Duty Und...

Page 10: ...ckwise is on Flame height should be approximately 1 2 Burner Valve If burner valve becomes too difficult to turn 1 Turn off gas to the unit 2 Remove knobs and control panel 3 Lift burner out 4 Loosen nut on front of valve and remove stem 5 Lubricate the valve stem with high temperature grease 6 Reassemble Upon completion turn gas on and check for leaks The valve should be turned on and off several...

Page 11: ...but it drains excess fat more quickly BE SURE YOUR BROILER BURNER VALVES ARE PROPERLY ADJUSTED to achieve a 550 F 650 F broiling surface DO NOT OVERFIRE as you will cause premature component failure BE SURE TO INSPECT AND CLEAN THE PERFORATED SCREENS REGULARLY to reduce flare up BE SURE TO KEEP THE RADIANT REFLECTORS AND HEAT SHIELDS CLEAN on low profile counter models to reduce flare up ...

Page 12: ...12 ...

Page 13: ...9 3 01279 3 01279 3 11 Cover Debris Rear 20793 4 20730 6 20332 7 39 Pilot Lighter 20535 4 20535 4 20535 4 12 Deflector Door 20934 1 20933 3 20932 5 40 Pilot Valve 01055 3 01055 3 01055 3 13A Radiant 20122 7 20122 7 20122 7 42A Valve Assy Burner N 02406 6 02406 6 02406 6 13B Radiant Cast Iron 20531 1 20531 1 20531 1 42B Valve Assy Burner LP 01003 0 01003 0 01003 0 14 Screw Cap w Shank 19847 1 19874...

Page 14: ...rked on the rating plate 5 Adequate air supply to the unit 6 The equipment is operated in the manner intended using the proper utensil for that type of appliance 7 Keep the equipment clean and have it checked periodically 8 Burner air adjustments mechanical maintenance and repairs should be performed by qualified service personnel If the equipment is not installed operated and maintained in accord...

Page 15: ...mation Serial No _____________________________________________ Model No _____________________________________________ Change No ____________________________________________ Name No of Part Model No Change No Serial No The Montague Company 1830 Stearman Avenue P O Box 4954 Hayward CA 94540 4954 P N 21508 2 8 08 ...