a) Strip approximately 1 inch (25 mm) of the cable outer jacket to be terminated in terminal blocks TB1
and TB3. Then strip approximately 0.25 inches (6 mm) of insulation off of each individual wire.
b) Refer to Wiring section and Table 2 to make all connections to terminal block TB1 (power), TB2
(alarms), TB3 (relays/control signals) and TB4 UTP video). On TB3, the COMMAND IN + (CI+) and
COMMAND IN - (CI-) connections must be used for Simplex operation. For Half Duplex operation,
the additional signals RESPONSE OUT + (RO+) and RESPONSE OUT - (RO-) must also be used.
Insert each wire into its proper terminal block location and tighten the screw.
c) Terminate the video (coaxial) cable with a BNC type male connector, if not previously done. Refer to
Wiring section for video connections for fiber-optic or ViconNet optional video transmissions.
d) Terminate the 8-conductor alarm cable or communication/relay cable.
8. Slide excess cable back up into the mount/pipe so that cable length is flush with the bottom of the
housing, approximately 8 - 9 inches (203 - 229 mm).
Note: There should be minimal wire slack at all connection points.
9. Install the terminal blocks TB1, TB2, TB3 and TB4 into the Customer Interface Board at the proper block
frames. Install the video BNC cable connector to the Customer Interface Board’s mating BNC connector
at location J1 (for coax installations) or connect twisted-pair video wires to screw terminal TB4 (for UTP
installations). Refer to the Wiring section for video connections for fiber-optic and ViconNet versions.
10. Swing the customer interface board back into place. If interface board was completely removed, be sure
to reinstall it correctly, with the white connector near the wall of the enclosure. Refer to Figure 16. After
wiring is complete, dress cables up over board
11. Configure the SurveyorVFT communication/protocol and address DIP switches on the main board at this
time. Refer to the Setting the DIP Switch section of this manual.
12. Lift the SurveyorVFT camera drive up to the housing and attach the housing’s safety cord clip to the
camera drive’s tab. See Figure 17. Allow the drive to hang from the housing. Insert the clip of the safety
cord from the lower dome into the hole on the inside of the housing. See label inside housing.
13. Align the tabs on the camera drive with the slots in the housing, matching up the two arrows on the
camera drive and the housing.
WARNING: Cables having excessive slack can cause damage to the SurveyorVFT when installed into the
housing.
Figure 16
Unlatching the Customer Interface
Board
XX134-07-00 Rev 908 SurveyorVFT Camera Dome System
4BInstallation
•
23
Summary of Contents for SVFT-C22
Page 2: ......
Page 4: ......
Page 6: ......
Page 18: ...10 3BIntroduction XX134 07 00 Rev 908 SurveyorVFT Camera Dome System...
Page 34: ...26 4BInstallation XX134 07 00 Rev 908 SurveyorVFT Camera Dome System NOTES...