Detailed Installation
These steps provide the most thorough and accurate instructions.
In-Ceiling Mount Model
This version of SurveyorVFT mounts in the ceiling and rests on the ceiling material occupying the space
between the lower ceiling and upper building frame. All mounting hardware is provided.
Use of the Provided Scribe
A small metal scribe is provided to assist in marking an accurate hole size in a ceiling tile for in-ceiling
installations. Use as follows:
1. Place a ceiling tile on a large flat surface, face up.
Figure 4
Use of the Scribe
2. Measure and make a small mark at position
A
from corner (11.9 in./302 mm). Refer to Figure 4.
3. Measure and make a small mark at position
B
(8.2 in./208 mm), placing the Scribe as
perpendicular to the
A-
edge as possible.
4. Place the Scribe across positions
B
and
C
.
Rotate the Scribe around center
C
for a full turn.
5. Cut out the circle, using a sharp tool, on the
scribed line.
In-Ceiling Overview
Figure 5
Ceiling Mount Model
The ceiling hole is cut using the scribe and the
enclosure is prepared with flexible conduit or
cabling. The enclosure is then lifted up through
ceiling hole and the flipper screws are turned and
tightened against the ceiling. Then the interface
board is wired. The camera drive is hung from
the enclosure’s safety cord and installed into the
enclosure. The indoor lower dome is then
snapped on. The SurveyorVFT is secured with
the flippers. The SurveyorVFT’s horizontal
position is determined by the hole placement.
Refer to Figure 5 for installation details.
14
•
4BInstallation
XX134-07-00 Rev 908 SurveyorVFT Camera Dome System