Chapter
13 Copper Testing
OneExpert DSL User's Guide
22052280, Rev. 015
April 2019
220
OneCheck POTS Closeout
This test offers a quick and easy way to check if a line is usable for POTS (5-point closeout).
It is accessed via its own icon on the home page under the OneCheck Copper section. The
OneCheck POTS Closeout is available to all ONX-580 products and does not require any option.
1. Press the
OneCheck POTS Closeout
icon to open the configuration screen.
2. The
Tone Phone Number
and the
Quiet Line Phone Number
are blank in the
beginning. You need to enter them for the test. The
Start
button is grayed out until
they are both selected. The
Use Same Number for Tone / Quiet Line
check box is
unchecked by default.
When this check box is unchecked, and you change the
Tone Phone Number
, two
different numbers will be displayed. If the box is
checked, it will assign the tone phone number to the
quiet line phone number (phone numbers are numeric
only, commas will produce a 1 second pause)
3. Once you selected the phone numbers, press the
Start
button. The next screen displays the running tests.
4. There is a battery check that will be required to pass
before the rest of the testing proceeds. The battery
check ensures that there is +/- 25 VDC on T/R (or A/B).
If the battery check fails, you will receive a message,
offering to retry the battery check or abort the test.
Aborting the test will not allow you to save the results.
5. The following test results with pass/fail indicators will
be displayed: DC current (mA), narrowband loss (dB),
circuit noise (dBr nC), power influence (dBr nC) and
balance (dB). Press the
Show Details
button for more
information.
Summary of Contents for OneExpert DSL ONX-580
Page 1: ...OneExpert DSL User s Guide ...
Page 6: ...OneExpert DSL User s Guide 22052280 Rev 015 April 2019 vi ...
Page 78: ...Chapter 3 Utilities OneExpert DSL User s Guide 22052280 Rev 015 April 2019 78 ...
Page 138: ...Chapter 6 Ethernet TE Testing OneExpert DSL User s Guide 22052280 Rev 015 April 2019 138 ...
Page 144: ...Chapter 7 Wiring Tools OneExpert DSL User s Guide 22052280 Rev 015 April 2019 144 ...
Page 158: ...Chapter 9 WiFi Testing OneExpert DSL User s Guide 22052280 Rev 015 April 2019 158 ...
Page 172: ...Chapter 11 Testing with SmartIDs OneExpert DSL User s Guide 22052280 Rev 015 April 2019 172 ...
Page 224: ...Chapter 13 Copper Testing OneExpert DSL User s Guide 22052280 Rev 015 April 2019 224 ...
Page 236: ...Chapter 14 Fiber Testing OneExpert DSL User s Guide 22052280 Rev 015 April 2019 236 ...