Chapter
13 Copper Testing
OneExpert DSL User's Guide
22052280, Rev. 015
April 2019
188
- Specify a value for the ground capacitance, in μF/mile (or other units
depending on your configuration).This value is used for capacitance
between Tip (A) to Ground (E), and Ring (B) to Ground (E).
- Press the
OK
button.
4. To specify the method to test opens/capacitance, press the
Tray
button, select
Opens
Method
, and then choose
2-terminal, 3-terminal, Enhanced 2-terminal, or
Enhanced 3-terminal
.
The
three terminal
is the default Opens mode that measures the capacitance across the
pair or from an earth reference to either wire in the pair using only two connections or
terminals
The three terminal method measures the capacitance across the pair in the same way
except the way it measures from an earth reference to either wire in the pair. Connect
all the other unused pairs, screen (shield) if any, and ground or earth to the unused (not
being tested) wire in the pair, using three terminals.
Three terminal mode is useful when testing a pair inside a multi-pair cable since all pairs
rotate or change their relative position inside the cable throughout the length of the
cable to help control crosstalk.
The enhanced terminal modes are specially designed to perform better in low-parallel or
high-series resistance environments, where normal opens meters have difficulty getting
accurate results. After selecting an enhanced mode, simply return to the measurement,
and test as you normally would. You will get more accurate results in resistive
environments.
NOTE:
When using the three terminal method and no earth terminal
is connected, you will get a non-zero result from each wire to
earth.
5. For greatest accuracy, VIAVI recommends that you compensate the opens measurement
to remove the effects of the test leads. To compensate the opens measurements:
• Swipe downward on the screen to access the Tray menu.
• Select the
Compensate OPENS
system key
• Follow the instructions on the screen to disconnect all test leads to perform test
lead compensation.
• Press
Compensate
.
The compensation stops automatically when finished.
6. Press the
Back
button to return to the Opens menu.
Summary of Contents for OneExpert DSL ONX-580
Page 1: ...OneExpert DSL User s Guide ...
Page 6: ...OneExpert DSL User s Guide 22052280 Rev 015 April 2019 vi ...
Page 78: ...Chapter 3 Utilities OneExpert DSL User s Guide 22052280 Rev 015 April 2019 78 ...
Page 138: ...Chapter 6 Ethernet TE Testing OneExpert DSL User s Guide 22052280 Rev 015 April 2019 138 ...
Page 144: ...Chapter 7 Wiring Tools OneExpert DSL User s Guide 22052280 Rev 015 April 2019 144 ...
Page 158: ...Chapter 9 WiFi Testing OneExpert DSL User s Guide 22052280 Rev 015 April 2019 158 ...
Page 172: ...Chapter 11 Testing with SmartIDs OneExpert DSL User s Guide 22052280 Rev 015 April 2019 172 ...
Page 224: ...Chapter 13 Copper Testing OneExpert DSL User s Guide 22052280 Rev 015 April 2019 224 ...
Page 236: ...Chapter 14 Fiber Testing OneExpert DSL User s Guide 22052280 Rev 015 April 2019 236 ...