OneExpert DSL User's Guide
22052280, Rev. 015
April 2019
Chapter
13 Copper Testing
185
Measuring resistance and leakage
Using the Multimeter, you can measure resistance to identify shorts,
grounds, and resistive faults.
1. Connect the Tip (A), Ring (B), and Ground (Earth) leads to the
line under test.
2. From the Copper menu, press the
Multimeter
button.
3. Select the
Ω
(Omega tab)
. The Resistance screen appears
and the test starts running.
In this example, the tests for Tip (T) and Ring (R) and Tip (T)
and Ground (G) are done and the Ring (R) and Ground (G)
test is running continuously. DC and AC Volts are listed for
each test (these values are available on the 580P instrument
only).
4. For greatest accuracy, VIAVI recommends that you
compensate the measurement to remove the effects of the
test leads. To compensate the opens measurements:
• Swipe downward on the screen to access the Tray menu.
• Select the
Compensate Resistance
system key.
• Follow the instructions on the screen to connect the black, red, and green leads
and perform test lead compensation.
• Press
Compensate
.
The compensation stops automatically when finished.
5. To change the resistance measurement, press
Continuous/Snapshot
. The current
selection is a larger text size.
6. Press the
Leakage/Non-Leakage
button in the lower right.
The Leakage measurement is basically the high-voltage
ohmmeter. The
Leakage
button enables the standard
Leakage measurement by default. To enable the 250V
Leakage (when available) select Options and then select the
250V Leakage
checkbox.
7. To save the results to a report, use the Tray menu.
8. To learn what your results mean, see
“Resistance” in
Chapter 15 “Test Results”
.
Measuring resistance and leakage is complete.
Summary of Contents for OneExpert DSL ONX-580
Page 1: ...OneExpert DSL User s Guide ...
Page 6: ...OneExpert DSL User s Guide 22052280 Rev 015 April 2019 vi ...
Page 78: ...Chapter 3 Utilities OneExpert DSL User s Guide 22052280 Rev 015 April 2019 78 ...
Page 138: ...Chapter 6 Ethernet TE Testing OneExpert DSL User s Guide 22052280 Rev 015 April 2019 138 ...
Page 144: ...Chapter 7 Wiring Tools OneExpert DSL User s Guide 22052280 Rev 015 April 2019 144 ...
Page 158: ...Chapter 9 WiFi Testing OneExpert DSL User s Guide 22052280 Rev 015 April 2019 158 ...
Page 172: ...Chapter 11 Testing with SmartIDs OneExpert DSL User s Guide 22052280 Rev 015 April 2019 172 ...
Page 224: ...Chapter 13 Copper Testing OneExpert DSL User s Guide 22052280 Rev 015 April 2019 224 ...
Page 236: ...Chapter 14 Fiber Testing OneExpert DSL User s Guide 22052280 Rev 015 April 2019 236 ...