Sending tones
The purpose of this test is to send a tone on a network cable. By default, the OneExpert
DSL sends tone on all the wires of a cable.
1. Do one of the following:
• If testing a telephone cable, connect RJ-11 cable to the RJ-11
Wiring
connector
on the right panel of the unit.
• If testing a network cable, connect RJ-45 cable to the RJ-45
Wiring
connector
on the right panel of the unit.
2. From the Wiring Tools menu, select
Wire Map
.
3. Select the
Toning
function key. The Trace Toning screen appears.
4. To start toning the cable, select one of the following:
• High-Low
– Sends a high tone follow by a low tone on all leads of
• the connected cable.
• Low Short High
– Sends a low tone followed by a short high tone on all leads
of the connected cable.
• High
– Sends a continuous high tone on all leads of the connected cable.
• Low
– Sends a continuous low tone on all leads of the connected cable.
5. After you finish the test, select
Off
.
Hub Flash
The hub flash function is used to send an intermittent link signal to flash the link status light
on the Ethernet hub. Using this test, you can locate which port on the hub is being used. This is
useful for troubleshooting when the test access port is in a different physical location than the
hub.
1. Connect an Ethernet cable from the Residential Gateway port to an
Ethernet
connector
on the side of the OneExpert DSL.
2. From the Wiring Tools menu, select
Hub Flash
.
3. If needed, change the settings for
Cadence, Rate, Duplex
, or
NIC Wiring
by either
pressing the setting or using the arrow keys to highlight a setting and then press the
OK
button.
4. Select
Start
to begin the test.
5. Go to the location of the hub and observe the link activity LEDs. The port that is
connected to the instrument will blink.
6. To end the Hub Flash test, press the
Stop
softkey.
Summary of Contents for OneExpert DSL ONX-580
Page 1: ...OneExpert DSL User s Guide ...
Page 6: ...OneExpert DSL User s Guide 22052280 Rev 015 April 2019 vi ...
Page 78: ...Chapter 3 Utilities OneExpert DSL User s Guide 22052280 Rev 015 April 2019 78 ...
Page 138: ...Chapter 6 Ethernet TE Testing OneExpert DSL User s Guide 22052280 Rev 015 April 2019 138 ...
Page 144: ...Chapter 7 Wiring Tools OneExpert DSL User s Guide 22052280 Rev 015 April 2019 144 ...
Page 158: ...Chapter 9 WiFi Testing OneExpert DSL User s Guide 22052280 Rev 015 April 2019 158 ...
Page 172: ...Chapter 11 Testing with SmartIDs OneExpert DSL User s Guide 22052280 Rev 015 April 2019 172 ...
Page 224: ...Chapter 13 Copper Testing OneExpert DSL User s Guide 22052280 Rev 015 April 2019 224 ...
Page 236: ...Chapter 14 Fiber Testing OneExpert DSL User s Guide 22052280 Rev 015 April 2019 236 ...