Measuring the distance to a short
The following procedure describes how to measure the distance to a short.
1. Connect the Tip (A), Ring (B), and Ground
(Earth) leads to the line under test.
2. From the Copper menu, select the
Multimeter
button.
3. Press the
Ω
(Omega)
tab. The Resistance screen appears.
4. Select
Options
and then select
Distance To Short
. The Distance to Short menu appears.
5. Press + or – to change the temperature or wire gauge, if needed.
You have measured the distance to a short.
NOTE:
Use this feature only when the resistance is 4 kΩ or less (4
kΩ or less is almost always a hard short). If there is no hard
short on Tip and Ring (A and B), the measurement will be
inaccurate.
NOTE:
For the resistive distance to be accurate, it is critical that you
enter the correct gauge and temperature.
Summary of Contents for OneExpert DSL ONX-580
Page 1: ...OneExpert DSL User s Guide ...
Page 6: ...OneExpert DSL User s Guide 22052280 Rev 015 April 2019 vi ...
Page 78: ...Chapter 3 Utilities OneExpert DSL User s Guide 22052280 Rev 015 April 2019 78 ...
Page 138: ...Chapter 6 Ethernet TE Testing OneExpert DSL User s Guide 22052280 Rev 015 April 2019 138 ...
Page 144: ...Chapter 7 Wiring Tools OneExpert DSL User s Guide 22052280 Rev 015 April 2019 144 ...
Page 158: ...Chapter 9 WiFi Testing OneExpert DSL User s Guide 22052280 Rev 015 April 2019 158 ...
Page 172: ...Chapter 11 Testing with SmartIDs OneExpert DSL User s Guide 22052280 Rev 015 April 2019 172 ...
Page 224: ...Chapter 13 Copper Testing OneExpert DSL User s Guide 22052280 Rev 015 April 2019 224 ...
Page 236: ...Chapter 14 Fiber Testing OneExpert DSL User s Guide 22052280 Rev 015 April 2019 236 ...