Page 101
5.8.3.2
MODULATION
5.8.3.3
PATH
Command Syntax:
{:ATC |:ATC5000NG}{:SET |:SETTINGS}{:GENA |:GENB |:GENC |:GEND |:GENE
|:GENF}{:MOD |:MODE}SP<CW | PULSE>CR
Description:
This command sets the selected generator to CW, pulse modulation or off. A”*” is returned if the
command is able to complete successfully or “?” if a failure occurs.
Default:
Pulse
Example:
:ATC:SET:GENA:MOD CW\r
Query:
:ATC:SET:GENA:MOD?\r
Return:
CW
Command Syntax:
{:ATC |:ATC5000NG}{:SET |:SETTINGS}{:GENA |:GENB |:GENC |:GEND |:GENE
|:GENF}{:PATH}SP<TOP | BOTTOM>CR
Description:
This command sets the selected generator path to the top or bottom antenna. A”*” is returned if
the command is able to complete successfully or “?” if a failure occurs.
Default:
The default Value depends of the scenario type selected.
MULTI (Multi-
Receiver)
XPDR (Transponder)
GenA
Top
Top
GenB
Top
Top
GenC
Bottom
Bottom
GenD
GenB
Bottom
Bottom
GenE
Top
Top
GenF
Top
Top
For the scenario type UAT, the default settings depend of the UAT Test Mode. The generators
GenD, GenE and GenF are disabled. Any command sent to generator disabled is considered an
invalid command.
UAT Test Mode
GenA
GenB
GenC
Normal
Top
Disabled Bottom
Overlapping
Top
Disabled Bottom
DME Fruit 12 µs
spacing
Top
Disabled Bottom
Retrigger Long ADS-
B Message
Top
Disabled Bottom
Retrigger Long
Ground Link
Message
Top
Disabled Bottom
1090 Pulse
Interference
Top
Top
Disabled
Ground Link
Message Invalid
MSO
Top
Disabled Bottom
Airborne Message
Invalid MSO
Top
Disabled Bottom
Doppler Test
Top
Disabled Bottom
Modulation
Frequency
Top
Disabled Bottom
DME Fruit 30 µs
spacing
Top
Disabled Bottom