Operation, Remote Operation
Scenario Commands
Rev. L0
ATC-5000NG ATC/DME Test Set Operation Manual
1-2-5
February 2020
Subject to Export Control. See Cover Page for details.
Page 43
5.7.2.3.1.P
NAVIGATION ACCURACY CATEGORY FOR VELOCITY
5.7.2.3.1.Q
NIC SUPPLEMENT-A
5.7.2.3.1.R
NIC SUPPLEMENT-B
5.7.2.3.1.S
NIC SUPPLEMENT-C
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:STAT: |:STATIC: |:DYN: |:DYNAMIC:}<intruder
no>{:SAOS}{:NACV}SP<numeric>CR
Description:
This command sets the selected intruder aircraft operational status squitter navigation accuracy
category for velocity field to the specified value.
Numeric:
0 to 7 (decimal ASCII)
Value
0
1
2
3
4
Meaning
Unknown or >10 m/s
<10 m/s
<3 m/s
<1 m/s
<0.3 m/s
Example:
:ATC:SCE:STAT:1:SAOS:NACV 3\r
Default:
0
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:STAT: |:STATIC: |:DYN: |:DYNAMIC:}<intruder
no>{:SAOS}{:NISA}SP<numeric>CR
Description:
This command sets the selected intruder aircraft operational status squitter NIC Supplement-A
field to the specified value.
Numeric:
0 to 1(decimal ASCII)
Example:
:ATC:SCE:STAT:2:SAOS:NISA 1\r
Default:
0
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:STAT: |:STATIC: |:DYN: |:DYNAMIC:}<intruder
no>{:SAOS}{:NISB}SP<numeric>CR
Description:
This command sets the selected intruder aircraft operational status squitter NIC Supplement-B
field to the specified value.
Numeric:
0 to 1 (decimal ASCII)
Example:
:ATC:SCE:DYN:2:SAOS:NISB 1\r
Default:
0
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:STAT: |:STATIC: |:DYN: |:DYNAMIC:}<intruder
no>{:SAOS}{:NISC}SP<numeric>CR
Description:
This command sets the selected intruder aircraft operational status squitter NIC Supplement-C
field to the specified value.
Numeric:
0 to 1 (decimal ASCII)
Example:
:ATC:SCE:DYN:2:SAOS:NISC 1\r
Default:
0