Operation, Remote Operation
Scenario Commands
Rev. L0
ATC-5000NG ATC/DME Test Set Operation Manual
1-2-5
February 2020
Subject to Export Control. See Cover Page for details.
Page 91
5.7.4.15.4
AUXILIARY STATE VECTOR PAYLOAD MESSAGE ELEMENT
5.7.4.15.5
MODE STATUS PAYLOAD MESSAGE ELEMENT
5.7.4.15.6
TARGET STATE PAYLOAD MESSAGE ELEMENT
5.7.4.15.7
PAYLOAD MESSAGE SCHEDULE INTERVAL ENABLE
5.7.4.15.8
PAYLOAD MESSAGE SCHEDULE INTERVAL POWER
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:DYN: |:DYNAMIC:}<intruder
no>{:UAT}{:ADSB:}<message number>{:PLASV}SP<numeric>CR
Description:
This command sets the auxiliary state vector payload message element of the ADS-B message
of the specified intruder. This command applies to ADS-B Messages with payload type code of
‘1’, ‘2’, ‘5’ and ‘6.’ The data message is padded on the right with zeros for a length 10
hexadecimal ASCII. The <intruder no> specifies the number of the intruder in the channel
grouping specified.
Numeric:
0 to FFFFFFFFFF (10 hexadecimal ASCII)
Example:
:ATC:SCE:DYN:1: UAT:ADSB:1:PLASV CCCCCCC\r
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:DYN: |:DYNAMIC:}<intruder
no>{:UAT}{:ADSB:}<message number>{:PLMS}SP<numeric>CR
Description:
This command sets the mode status payload message element of the ADS-B message of the
specified intruder. This command applies to ADS-B Messages with payload type code of ‘1’ and
‘3.’ The data message is padded on the right with zeros for a length 24 hexadecimal ASCII. The
<intruder no> specifies the number of the intruder in the channel grouping specified.
Numeric:
0 to FFFFFFFFFFFFFFFFFFFFFFFF (24 hexadecimal ASCII)
Example:
:ATC:SCE:DYN:1:UAT:ADSB:1:PLMS AAAAAAAAAAAAAAAAAA\r
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:DYN: |:DYNAMIC:}<intruder
no>{:UAT}{:ADSB:}<message number>{:PLTS}SP<numeric>CR
Description:
This command sets the intruder state payload message element of the ADS-B message of the
specified intruder. This command applies to ADS-B Messages with payload type code of ‘3’, ‘4’
and ‘5.6.’ The data message is padded on the right with zeros for a length 10 hexadecimal
ASCII. The <intruder no> specifies the number of the intruder in the channel grouping specified.
Numeric:
0 to FFFFFFFFFF (10 hexadecimal ASCII)
Example:
:ATC:SCE:DYN:1:UAT:ADSB:3:PLTS EEEEEEE\r
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:DYN: |:DYNAMIC:}<intruder
no>{:UAT}{:ADSB:}<message number>{:INT: |:INTERVAL:}<interval number>{:ENA
|:ENABLE}SP{ON | OFF}CR
Description:
This command enables or disables the selected ADS-B payload message interval for the
selected intruder. The <intruder no> specifies the number of the intruder in the channel grouping
specified.
Example:
:ATC:SCE:DYN:1:UAT:ADSB:2:INT:1:ENA ON\r
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:DYN: |:DYNAMIC:}<intruder
no>{:UAT}{:ADSB:}<message number>{:INT: |:INTERVAL:}<interval number>{:PWR
}SP<numeric>CR
Description:
This command sets the power level of the ADS-B payload message interval for the selected
intruder. The <intruder no> specifies the number of the intruder in the channel grouping specified.
Numeric:
-110 to 5 dBm (decimal ASCII)
Example:
:ATC:SCE:DYN:1:UAT:ADSB:1:INT:1:PWR -80\r