Operation, Remote Operation
Scenario Commands
1-2-5
ATC-5000NG ATC/DME Test Set Operation Manual
Rev. L0
Page 48
Subject to Export Control. See Cover Page for details.
February 2020
5.7.2.3.2
AIRCRAFT OPERATIONAL STATUS MESSAGE SCHEDULE
Airborne Operational Status squitter is transmitted by the ATC-5000NG at a rate of 2.0 seconds.
Dynamic intruders (targets) allow definition of multiple time intervals where the Airborne Operation Status
squitter can be enabled or disabled.
Static intruders (targets) allow the user to enable or disable the Airborne Operational Status squitter for
the entire scenario.
5.7.2.3.2.A
DYNAMIC AOS SCHEDULE
5.7.2.3.2.A.1
INTERVAL ENABLE
5.7.2.3.2.A.2
INTERVAL QUANTITY
5.7.2.3.2.A.3
INTERVAL START TIME
5.7.2.3.2.A.4
INTERVAL STOP TIME
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:DYN: |:DYNAMIC:}<intruder no>{:SAOS}{:INT:
|:INTERVAL:}<interval number>{:ENA |:ENABLE}SP{ON | OFF}CR
Description:
This command enables or disables the aircraft operational status squitter message of the
specified intruder.
Example:
:ATC:SCE:DYN:1:SAOS:INT:1:ENA ON\r
Default:
On
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:DYN: |:DYNAMIC:}<intruder no>{:SAOS}{:NINT
|:NINTERVALS}SP<numeric>CR
Description:
This command sets the number of aircraft operational status squitter message intervals for the
selected intruder. The spaces not defined between intervals are considered off; therefore,
only
the user
can define
the intervals where
the message
is
transmitted
.
Numeric:
0 to 255 (decimal ASCII)
Example:
:ATC:SCE:DYN:1:SAOS:NINT 2\r
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:DYN: |:DYNAMIC:}<intruder no>{:SAOS}{:INT:
|:INTERVAL:}<interval number>{:BEGIN}SP<numeric>CR
Description:
This command sets the start time for the selected aircraft operational status squitter message
interval for the selected intruder. The spaces not defined between intervals are considered off;
therefore,
only
the user
can define
the intervals where
the message
is
transmitted
.
Numeric:
0 to 6550 seconds (decimal ASCII). Resolution is 0.1 seconds.
Example:
:ATC:SCE:DYN:1:SAOS:INT:2:BEGIN 25\r
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:DYN: |:DYNAMIC:}<intruder no>{:SAOS}{:INT:
|:INTERVAL:}<interval number>{:END}SP<numeric>CR
Description:
This command sets the stop time for the selected aircraft operational status squitter message
interval for the selected intruder. The spaces not defined between intervals are considered off;
therefore,
only
the user
can define
the intervals where
the message
is
transmitted
.
Numeric:
0 to 6550 seconds (decimal ASCII). Resolution is 0.1 seconds.
Example:
:ATC:SCE:DYN:1:SAOS:INT:1:END 25\r