Operation, Remote Operation
Scenario Commands
Rev. L0
ATC-5000NG ATC/DME Test Set Operation Manual
1-2-5
February 2020
Subject to Export Control. See Cover Page for details.
Page 61
5.7.2.14.5
RANGE
5.7.2.14.6
TRACK
5.7.2.14.7
VELOCITY
5.7.2.15
START TIME
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:STAT: |:STATIC: |:DYN: |:DYNAMIC:}<intruder
no>{:RAN |:RANGE}SP<numeric>CR
Description:
This command sets the selected intruder to the specified range from own aircraft.
Numeric:
0 to 150 nmi (decimal ASCII)
NOTE:
The intruder can be defined by range and bearing or
latitude and longitude. If the intruder is defined using range and bearing, the ATC-5000NG
calculates the latitude and longitude of the intruder. If the intruder is defined using latitude and
longitude, the ATC-5000NG calculates the range and bearing.
Default:
0 nmi
Example:
:ATC:SCE:DYN:1:RAN 27.5\r
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:STAT: |:STATIC: |:DYN: |:DYNAMIC:}<intruder
no>{:TRA |:TRACK}SP<numeric>CR
Description:
This command sets the selected intruder track angle.
Numeric:
-180 to 180 degrees (decimal ASCII)
0 to 360 degrees (decimal ASCII)
NOTE:
The track information is only used for the velocity
squitter of an extended Mode S when the intruder is a static intruder.
Default:
0
Example:
:ATC:SCE:DYN:1:TRA 150\r
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:STAT: |:STATIC: |:DYN: |:DYNAMIC:}<intruder
no>{:VEL |:VELOCITY}SP{NODATA|<numeric>}CR
Description:
This command sets the selected intruder to the specified velocity. If velocity data is not available,
then use the keyword “NODATA”. If velocity data is not available then the E/W velocity, N/S
velocity and Ground Speed information is not available.
Numeric:
0 to 5782 knots (decimal ASCII)
NOTE:
The track information is only used for the velocity
squitter of an extended Mode S when the intruder is a static intruder.
Default:
0
Example:
:ATC:SCE:DYN:1:VEL 250\r
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:STAT: |:STATIC: |:DYN: |:DYNAMIC:}<intruder
no>{:BEGIN}SP<numeric>CR
Description:
This command sets the scenario time when the intruder becomes active.
Numeric:
0 to 6550 seconds (decimal ASCII)
Default:
0
Example:
:ATC:SCE:DYN:1:BEGIN 25\r
Summary of Contents for 138156