5.7.2.19.1.M
MCP/FCU MODE BITS
5.7.2.19.1.N
NAVIGATION ACCURACY CATEGORY FOR POSITION
5.7.2.19.1.O
RESERVED FOR ADS-R FLAG
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:STAT: |:STATIC: |:DYN: |:DYNAMIC:}<intruder
no>{:STARGET}{:SMD}SP<numeric>CR
Description:
This command sets the selected intruder target state and status squitter status of MCP/FCU
mode bits field to the specified value, if the intruder is an extended Mode S.
Numeric:
0 to 1 (decimal ASCII)
Value
0
1
Meaning
No Mode Information/Invalid
Valid Mode Information in bits 80,81,82,84
Default:
0
Example:
:ATC:SCE:STAT:1:STARGET:SMD 1\r
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:STAT: |:STATIC: |:DYN: |:DYNAMIC:}<intruder
no>{:STARGET}{:NACP}SP<numeric>CR
Description:
This command sets the selected intruder target state and status squitter navigation accuracy
category for position field to the specified value, if the intruder is an extended Mode S.
Numeric:
0 to 15 (decimal ASCII)
Value
0
1
2
3
4
5
6
7
8
9
10
11
12 to 15
NAC
P
EPU ≥10 Nm
EPU <10 Nm
EPU <4 Nm
EPU <2 Nm
EPU <1 Nm
EPU <0.5 Nm
EPU <0.3 Nm
EPU <0.1 Nm
EPU <0.05 Nm
EPU <30 m and VEPU <45 m
EPU <10 m and VEPU <15 m
EPU <3 m and VEPU <4m
Reserved
Default:
0
Example:
:ATC:SCE:DYN:1:STARGET:NACP 4\r
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:STAT: |:STATIC: |:DYN: |:DYNAMIC:}<intruder
no>{:STARGET}{:ADR}SP<numeric>CR
Description:
This command sets the selected intruder target state and status squitter reserved for ADS-R flag
field to the specified value, if the intruder is an extended Mode S.
Numeric:
0 to 1 (decimal ASCII)
Default:
0
Example:
:ATC:SCE:DYN:1:STARGET:ADR 1\r