Operation, Remote Operation
Scenario Commands
Rev. L0
ATC-5000NG ATC/DME Test Set Operation Manual
1-2-5
February 2020
Subject to Export Control. See Cover Page for details.
Page 69
5.7.2.19.1.P
SELECTED HEADING STATUS
5.7.2.19.1.Q
SOURCE INTEGRITY LEVEL SUPPLEMENT
5.7.2.19.1.R
SUBTYPE
5.7.2.19.1.S
SURVEILLANCE INTEGRITY LEVEL
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:STAT: |:STATIC: |:DYN: |:DYNAMIC:}<intruder
no>{:STARGET}{:SHS}SP<numeric>CR
Description:
This command sets the selected intruder target state and status squitter selected heading status
field to the specified value, if the intruder is an extended Mode S.
Numeric:
0 to 1 (decimal ASCII)
Value
0
1
Meaning
Selected Heading Invalid
Selected Heading Valid
Default:
0
Example:
:ATC:SCE:DYN:1:STARGET:SHS 1\r
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:STAT: |:STATIC: |:DYN: |:DYNAMIC:}<intruder
no>{:STARGET}{:SILS}SP<numeric>CR
Description:
This command sets the selected intruder target state and status squitter source integrity level
supplement field to the specified value, if the intruder is an extended Mode S (DO-260B).
Numeric:
0 to 1 (decimal ASCII)
Value
0
1
Meaning
Probability of exceeding NIC Radius of Containment “per hour”
Probability of exceeding NIC Radius of Containment “per
sample”
Default:
0
Example:
:ATC:SCE:DYN:1:STARGET:SILS 1\r
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:STAT: |:STATIC: |:DYN: |:DYNAMIC:}<intruder
no>{:STARGET}{:SUBTYPE}SP<numeric>CR
Description:
This command sets the selected intruder target state and status squitter subtype field to the
specified value, if the intruder is an extended Mode S (DO-260B).
Numeric:
0 to 1 (decimal ASCII)
Default:
0
Example:
:ATC:SCE:DYN:1:STARGET:SUBTYPE 1\r
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:STAT: |:STATIC: |:DYN: |:DYNAMIC:}<intruder
no>{:STARGET}{:SIL}SP<numeric>CR
Description:
This command sets the selected intruder target state and status squitter surveillance integrity
level field to the specified value, if the intruder is an extended Mode S.
Numeric:
0 to 3 (decimal ASCII)
Value
0
1
2
3
Meaning
Unknown
1x10
-3
per flight hour
1x10
-5
per flight hour
1x10
-7
per flight hour
Default:
0
Example:
:ATC:SCE:DYN:1:STARGET:SIL 2\r
Summary of Contents for 138156