30
The display shows information about the operating mode of the burner - the burner is in the mode of
ignition of fuel:
S
-
+
ESC
After removal of debris by means of a fan the fuel feeder starts to supply the initial quantity of fuel and the
burner performs the ignition of fuel. The display shows the operating mode "IGNITION 1" (ignition) - this is the
first attempt (denoted as 1) of ignition of fuel which lasts for a period that can be set in the service software;
After a successful ignition of fuel the operation of burner will continue to operate according to the factory
setting in order to stabilize the combustion process according to the data on the display - see the Figure
below:
S
-
+
ESC
TRANS.:10kW
the burner is in the mean operating mode and it works with a heat output of 10 kW;
The burner from the mode of stabilization passes into automatic mode. The performance will change
depending on the desired temperature of outlet water from the boiler.
S
-
+
ESC
•
COMBUST 5 – 32kW
the degree of operating heat output of the burner (in the event that the
burner works in the degree 5 of heat output and its power is 32 kW);
•
72
°
temperature of outlet water from the boiler, [°C];
•
FC: 98%
intensity of flame measured by means of a photosensor [%];
IGNITION 1 150
ON 32
o
FC: 0%
TRANS. : 10kW
ON 32
o
FC: 65%
COMBUST 5 32kW
ON 72
o
FC: 98%