33
Switching off the burner by means of external control module
Turn off the burner by pressing START OF BURNER. Then the control module of burner performs a
"controlled shutdown process" during which the fan is kept in operation (burner is cooled down) while
simultaneously are monitored the operating parameters. After cooling the burner (to the room temperature)
switch off the burner by means of its disconnecting from the main power supply.
Faulty statuses of the burner
When a faulty status occurs on the burner, then the display of control module shows the message of alarm. A
detailed description of error messages and their solutions can be found in Tab. no. 4 and 5
ATTENTION:
•
In case of boiler overheating the safety thermostat is activated. Safety thermostat must be manually
reset: Safety thermostat can be turned on only after the temperature has dropped below the set value.
We shall unscrew the black cap of safety thermostat and with a suitable tool we press the button. In
case of a repeated shutdown of the safety thermostat the boiler has to be shut down and then the cause
of repeated overheating of the boiler must be found out. After checking of boiler and burner and
determining and correction of the cause of overheating restart the burner by switching off the power
supply and its subsequent switching on.
•
In case of activation of thermal sensor against the penetration of burning fuel the fuel feeder switches off
and the burner becomes extinct. After finding the cause of high temperature on the knee of burner we
reset the fault by switching off and on of the burner. In the event of damage to the sensor this must be
replaced by a service worker.
The list of latest 10 faults that occurred during the burner operation
To check the latest faults that occurred during the burner operation, enter into the menu „LOG“.
S
-
+
ESC
The display of control module of burner shows the selected item „LOG“ in menu, i.e. the number of faults in
the list of faults and their codes.
To exit the menu press the button „ESC“.
Fault conditions and the procedure for their solution are described in Tab. no. 4 and 5
Reset of faulty statuses of burner
We carry out the reset by switching off and then switching on of the main switch in the control box of boiler.
LOG error 1:22
EXIT