32
ATTENTION: In case that the fuel has changed (for instance the class of pellets has changed), then an
additional adjustment of operating parameters of the burner should be done.
NOTE:
The burner in case of a change of the degree of heat output automatically re-adjusts the fan
power and the quantity of fuel;
Stopping of the operating mode of the burner by switching off the button „START OF
BURNER“
Use "START OF BURNER" button for switching on and the operation of the burner and the subsequent
switching off and stopping of burner. The display of control module after switching off the burner shows the
message: „FINAL COMBUSTION“ (the final combustion).
ATTENTION: To turn off the burner, use the "START OF BURNER". Do not turn off power supply of burner.
The reason for this measure is that the button "START BURNER" activates the controlled process of
switching off of the control module of burner, which also cools the unit and ensures that all carbonaceous
residues are burnt, and thus retains the reliability and performance of the burner.
Stopping of the operating mode of burner by setting the item in menu of its control module.
To stop the burner operation is necessary to proceed as follows:
• Press and hold the "ESC" (longer than 5 seconds);
• Give an answer to the question "Make final comb.?" (should be carried out the final combustion?) that
appears on the display of control module by selecting "YES" (yes);
If you select "YES" (yes), the display shows "MAN FINAL COMB" (final combustion) and the control module
will shut down the burner.
Other way to stop the operation of the burner, see below:
To stop the burner operation it is necessary to enter into the item "MAKE FINAL COMB." (Carry out the final
combustion) in the menu of control module of burner.
S
-
+
ESC
To confirm your choice press "S"; in case of refusal press "ESC" and in for moving to other items, use the "+"
and "-".
S
-
+
ESC
After the extinction of the burner, the display shows "Activate" (initial screen display).
If the burner is not in use for a long time, unplug it from the power supply and then clean the combustion
chamber, combustion grate and photosensor from deposition of ashes.
MAKE FINAL COMB.
ENTER
EXIT
Make final comb.?
[YES]