The Loopback application in the main menu allows the user to establish a manual loopback on the test set. The loopback
function is used when an end-to-end test needs to be performed with one of the test partners in software loopback mode. The
loopback function will loopback the incoming traffic to the test set back into the network under test.
The type of traffic that the loopback function loops back will depend on the type of test layer configured (Layer 1, 2, 3, or 4).
Additional criteria can be set to allow only messages with specific criteria to be looped back. To specify loopback parameters,
select the desired parameter and choose
Enable
from the drop-down menu. Tap on the box and input a value or select one of
the drop-down menu choices:
Layer 1
: All incoming traffic to the Rx loopback interface will be sent out unaltered to the Tx loopback interface.
Layer 2, 3, 4, & MPLS-TP
: In a Layer 2 or 3 loopback all incoming test traffic will be looped back.
The loopback function will swap the MAC destination and MAC Source addresses (for Layer 2) or MAC and IP
destination and source addresses (for Layer 3).
All incoming frames with CRC errors will be dropped, similar to what an Ethernet switch does.
All broadcast and multicast frames will be dropped including any incoming unicast frames that have the MAC
Source address equal to the MAC Destination address.
Loopback Parameters
: The following parameters are available on Layer 2, 3 and 4. For more information on the
parameters, please see
in the BERT section. It is possible to enable any of these
parameters to create a customer loopback filter. For example, enabling a filter with VLAN 64, Priority 7, will only
loop back traffic corresponding to these values.
VLAN ID
VLAN Priority
MAC Source
MAC Destination
IP Source Address (Layer 3 & 4 only)
IP Destination (Layer 3 & 4 only)
Precedence (Layer 3 & 4 only)
TOS Value (Layer 3 & 4 only)
UDP SPort (Layer 4 only)
UDP DPort (Layer 4 only)
LSP Label (MPLS-TP Layer only)
PW Label (MPLS-TP Layer only)
Press
Start
to begin loopback.
indicates that loopback is in progress. The
Results
tab displays current test results. Please
see
for information on these tabs.
Loopback Setup
Loopback In Progress
RXT-3900 e-Manual D07-00-111P Rev A00
Summary of Contents for RXT3900
Page 1: ...RXT 3900 e Manual D07 00 111P Rev A00...
Page 19: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Page 50: ...RXT 3900 e Manual D07 00 111P Rev A00...
Page 74: ...RXT 3900 e Manual D07 00 111P Rev A00...
Page 75: ...RXT 3900 e Manual D07 00 111P Rev A00...
Page 119: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Page 240: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Page 282: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Page 294: ...Go back to top Go back to TOC 13 15 IP Monitoring RXT 3900 e Manual D07 00 111P Rev A00...
Page 296: ...Net Wiz Trace Route Setup Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Page 363: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Page 377: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...