13.4.6 Peer-to-Peer and Asymmetric Testing
Remote Partner Control
When the local unit connects to the remote (peer) partner, it loads the same configuration profile (header, traffic, and frame size)
to the remote partner, with the MAC and IP addresses inverted. From the peer-to-peer menu, asymmetric testing becomes
available.
Asymmetrical links provide different line rates in the two directions. To verify the information for both the low and the high rates
of the link, the user needs to send a test signal from one instrument located at one end of the link to an instrument at the other
end of the link and vice versa to test traffic capacity. The two test instruments have to be synchronized because the tests defined
in RFC 2544 require the receiver to know the contents of the test signal to be transmitted in detail.
The test set offers an automated RFC 2544 test application to perform throughput, frame loss, and burstability tests in a local-
remote unit setup. The user first configures the test setup in the local unit. Once initiated, the local unit transfers the setup
information to the remote unit via the line under test. Upon completion, the remote unit transfers the test results back to the local
unit, enabling the user to read the results for both directions of the link on the local unit.
Asymmetric Testing Setup
1. Tap on the
P2P Setup
button on the right side of the screen to start the step-by-step setup process.
2. Set the Local unit as a
Controller
or
Responder
.
At any time during the process, tap on the right side navigation buttons to move to the
NEXT
screen, return to the
Previous
screen, or
Exit
the setup guide
.
Set the Local unit as Controller or Responder
Unit as Controller Setup Process
Step 1:
Select Controller.
RXT-3900 e-Manual D07-00-111P Rev A00
Summary of Contents for RXT3900
Page 1: ...RXT 3900 e Manual D07 00 111P Rev A00...
Page 19: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Page 50: ...RXT 3900 e Manual D07 00 111P Rev A00...
Page 74: ...RXT 3900 e Manual D07 00 111P Rev A00...
Page 75: ...RXT 3900 e Manual D07 00 111P Rev A00...
Page 119: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Page 240: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Page 282: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Page 294: ...Go back to top Go back to TOC 13 15 IP Monitoring RXT 3900 e Manual D07 00 111P Rev A00...
Page 296: ...Net Wiz Trace Route Setup Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Page 363: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Page 377: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...