16. SERVICING & PARTS REPLACEMENT
Always turn off the gas supply and allow the appliance to cool completely
before commencing any servicing (The appliance inlet “T” connector
incorporates an isolating valve).
It is recommended that, at least once a year, the appliance is disconnected and
the fireplace opening checked and cleared of any debris.
This product uses fuel effect pieces and a burner compartment rear wall
containing Refractory Ceramic Fibres (RCF), which are man-made vitreous
silicate fibres. Excessive exposure to these materials may cause irritation to
eyes, skin and respiratory tract. Consequently, it is important to take care when
handling these articles to ensure that the release of dust is kept to a minimum.
To ensure that the release of fibres from these RCF articles is kept to a
minimum, during installation and servicing we recommend that you use a HEPA
filtered vacuum to remove any dust and soot accumulated in and around the
fire before and after working on the fire. When replacing these articles we
recommend that the replaced items are not broken up, but are sealed within a
heavy duty polythene bag, clearly labelled as RCF waste. RCF waste is classed
as a stable, non-reactive hazardous waste and may be disposed at a landfill
licensed to accept such waste. Protective clothing is not required when
handling these articles, but we recommend you follow the normal hygiene rules
of not smoking, eating or drinking in the work area and always wash your
hands before eating or drinking.
Check that the appliance is clean and that soot or debris is not blocking the gaps
between the ceramic fuel effect pieces causing an imperfect flame.
Check that soot or debris is not impairing the electrode spark or pilot burner.
Check that soot or debris is not blocking any of the holes in the main burner.
After servicing, make sure that the ceramic fuel effect pieces are replaced
correctly as described in the installer and owner guide supplied with the ceramic fuel
effect. The ceramic fuel effect guide should be placed inside or attached to this guide.
Always test for gas soundness and spillage after servicing the appliance.
Page 42
©
Baxi Heating U.K. Limited 2010.
INSTALLER GUIDE
Summary of Contents for 954