heard
.
This sound is caused by an electromagnetic valve shutting off the gas supply
through the tap. The valve is located in the body of the tap. The valve should operate
within 60 seconds of the pilot going out
.
If the valve does not operate within this
time limit do not allow the appliance to be used until the fault has been corrected.
This monitoring system must not be adjusted, bypassed or put out of
operation.
This monitoring system, or any of its parts, must only be exchanged using
authorised parts.
3.
Open the isolating valve on the inlet ‘T’ connector. Screw on the end cap and test
for leaks.
4.
Set the slider to the “Off’” (“O”) position.
15. FINAL REVIEW
1.
COMPLETE THE INFORMATION IN THE WARRANTY AND SERVICE SECTION
OF THE OWNER GUIDE (See last pages of the OWNER guide).
2.
Visually inspect the appliance. Clean off any marks incurred during installation.
Metal Parts
Clean the metal parts with a slightly damp lint free non-abrasive cloth and then
dry.
Do not use abrasive cleaners as these will scratch the fire surface.
Chic, Envy and Westminster fascia -
Clean the metal parts with a slightly damp
cloth and then dry. If this does not work apply a very small amount of ‘baby oil’ to a
lint free non-abrasive cloth and wipe over the surface. Use a clean cloth to wipe off
the oil.
3.
Advise the customer how to operate the fire.
4.
Explain to the customer that the appliance has a flame failure and spillage
monitoring system. Point out the explanation of this system shown in the owner guide.
Advise that if the fire goes out for any reason, wait at least three minutes before
relighting. Stress that if the monitoring system repeatedly shuts off the fire, the
appliance should be switched off and a specialist should be consulted. Point out the
lighting instruction details in the owner guide.
5.
Advise that the fire may give off a slight odour while new. This is quite normal and it
will disappear after a short period of use.
6.
Advise that any cleaning must only be carried out when the fire is off and cold.
7.
Advise the customer that they should read the Owner guide before operating the
fire and always follow the advice in the section headed “Cleaning your fire”.
8.
Advise the customer that the appliance will operate to its maximum potential if the
flue is primed during the first 20 – 30 minutes of use. To do this, simply turn the
control to its highest setting. This will also burn off any carbon deposits that may have
formed during previous use. If using the appliance for long periods it is beneficial to
change between settings. This will also help to remove any carbon deposits that may
form during use.
9.
Recommend that the appliance should be serviced and the chimney inspected by a
Page 40
©
Baxi Heating U.K. Limited 2010.
INSTALLER GUIDE
Summary of Contents for 954
Page 20: ...Page 20 Baxi Heating U K Limited 2010 INSTALLER GUIDE Figure 7 Pack contents...
Page 21: ...Page 21 Baxi Heating U K Limited 2010 INSTALLER GUIDE Figure 7 Pack contents continued...
Page 22: ...Page 22 Baxi Heating U K Limited 2010 INSTALLER GUIDE Figure 7 Pack contents continued...
Page 64: ...Baxi Heating U K Limited 2010...