13-5
Valco Cincinnati, Inc.
Section 13 - Operation
MC032 - MCP-25 Control
Delay:
Delay:
Delay:
Delay:
Delay:
If the start of the glue pattern begins later than the value seen in the glue
pattern edit menu, increase the “Ton” value (0.1-25 milliseconds) in the valve
setup menu.
If the start of the glue pattern begins sooner than the value seen in the glue
pattern edit menu, decrease the “Ton” value (0.1-25 milliseconds) in the valve
setup menu.
Pattern length:
Pattern length:
Pattern length:
Pattern length:
Pattern length:
If the pattern is longer than the value seen in the glue pattern edit menu,
increase the “Toff” value (0.1-25 milliseconds) in the valve setup menu.
If the pattern is shorter than the value seen in the glue pattern edit menu,
decrease the “Toff” value (0.1-25 milliseconds) in the valve setup menu.
5.
If necessary, adjust “Ton” and “Toff” values.
Adjusting the Glue-Pattern Position