8-7
Valco Cincinnati, Inc.
Section 8 - Glue Pattern Edit Menu
MC032 - MCP-25 Control
If you selected jogging mode (mode 3) in the mode-selection screen, follow
these steps:
1.
Enter the following parameters by moving the cursor onto the
field that you want to change and entering the values:
Vjog
Vjog
Vjog
Vjog
Vjog—The maximum speed until jogging cycle operates. Over
this speed, the gluing becomes standard. Maximum
allowable is 300 m/min.
Tjog
Tjog
Tjog
Tjog
Tjog—The dot size valve opening time in
milliseconds. Maximum allowable is 9.9 milliseconds.
Dot gap
Dot gap
Dot gap
Dot gap
Dot gap—The length of the gap between each single dot.
Maximum allowable is 199 mm.
Selecting a Mode - Continued
To enter or edit a glue pattern in standard mode (0), stitch mode (2) or
jogging mode (3), follow these steps:
1.
Using the arrow keys, move the cursor to the field that you want
to change.
Entering/
Editing
a Glue Pattern
Step 1—Glue-Pattern-Edit Menu with Standard, Stitch, or Jogging Mode
Selected (Standard Mode is Shown)
2.
Using the either the numeric keypad or the scroll buttons (+10,
+1, -1, -10), enter a new value for the field.
Newly entered or changed values will
be immediately accepted by the control.
Therefore, values must be entered
completely and quickly.
The cursor will automatically move to
the next display field when the ENTER
button is pressed. However, the arrow
keys can also be used to move to a
desired display field.
Step 1—Glue-Pattern-Edit Menu with Continuous-Gluing Mode Selected