8-3
Valco Cincinnati, Inc.
Section 8 - Glue Pattern Edit Menu
MC032 - MCP-25 Control
3
33
33
Start Point of Pattern 2 (Pattern-Delay 2)
Start Point of Pattern 2 (Pattern-Delay 2)
Start Point of Pattern 2 (Pattern-Delay 2)
Start Point of Pattern 2 (Pattern-Delay 2)
Start Point of Pattern 2 (Pattern-Delay 2)
The distance from the leading edge of the product to the start of
the second glue pattern. This value must be entered in either
millimeters or 1/100 inches, depending on the setup of the
control. Maximum allowable delay is 9999 mm or 99.99 inches.
Pressing F5 (>>>) displays the values for glue patterns 3, 4, and
5.
4
44
44
Valve Number
Valve Number
Valve Number
Valve Number
Valve Number
This field indicates the number of the valve to which the
information on the screen pertains. Up to 8 valves are available
for a job. Pressing F3 (FORWARD) or F4 (BACK) allows you to
select the information for a different valve.
5
55
55
Cell-to-Gun Dimension
Cell-to-Gun Dimension
Cell-to-Gun Dimension
Cell-to-Gun Dimension
Cell-to-Gun Dimension
Enter the distance between the glue valve’s nozzle opening and
the middle of the scanner. Enter this value in millimeters or 1/100
inches depending on the setup of your MCP-25 (see
Section 11—
Setup Menu). Maximum distance = 19999 mm or 199.99 inches.
6
66
66
Scanner Assignment
Scanner Assignment
Scanner Assignment
Scanner Assignment
Scanner Assignment
Determine which scanner (or start signal) to use with the glue
pattern of a channel (valve). If all scanners are installed, you can
choose any one of four scanners for a channel (valve).
Glue-Pattern-Edit Parameters -
Continued
Scanner 5 can be used as an encoder
start signal (0 signal). (See
Section 11—
Setup Menu, “Encoder Configuration”.)
7
77
77
Job Name
Job Name
Job Name
Job Name
Job Name
This field displays the name of the job. The job name cannot be
edited in the glue-pattern-edit screen.
8
88
88
Repeat Factor
Repeat Factor
Repeat Factor
Repeat Factor
Repeat Factor
This field contains the number of identical, consecutive glue
patterns (based on the first pattern specified).
If repeat factor = 1
If repeat factor = 1
If repeat factor = 1
If repeat factor = 1
If repeat factor = 1, the glue pattern (as entered) will be applied
one time (there are a maximum of 5 independent glue lines).
If repeat factor = 2 to 99
If repeat factor = 2 to 99
If repeat factor = 2 to 99
If repeat factor = 2 to 99
If repeat factor = 2 to 99, the complete glue pattern will be
applied by the valve (maximum of 4 glue lines) 2 to 99 times.
The pattern startpoint (delay) of the repetition is the last startpoint
given in the glue-pattern-edit menu. Therefore, it is important that
the corresponding glue pattern length is set to 0. The difference
between the first startpoint and the last startpoint is the distance
between the pattern repetitions.