Installation instructions for geoTHERM exclusive VWS 0020051614_00
80
13 Technical
data
Description
Unit
VWS 63/2 230 V GB
VWS 83/2 230 V GB
VWS 103/2 230 V GB
Article number
-
0010007274
0010007275
0010007276
Height with connections
Width
Depth without pillars
Depth with pillars
mm
mm
mm
mm
1930
600
650
840
Total weight
- with packaging
- without packaging
- ready for operation
Transport weight
- Domestic hot water cylinder module
- Heat pump module
kg
kg
kg
kg
kg
231
216
402
100
106
239
224
411
100
114
242
227
415
100
117
Rated voltage
- Heating circuit/Compressor
- Control circuit
- Auxiliary heating
-
1/N/PE 230 V 50 Hz
1/N/PE 230 V 50 Hz
1/N/PE 230 V 50 Hz
Alternative operation (condition upon
delivery 4 kW)
A
16/20
25/25
Parallel operation
A
25/35
35/50
Bypass feeder WP-Tariff
- Separate compressor
- separate auxiliary heating 2/4 kW
A
A
16
16/20
25
16/20
25
16/20
Bypass feeder special tariff
- alternative operation (condition upon
delivery 4kW)
A
16/20
25/25
25/25
Parallel operation
- pumps and controllers
A
A
25/35
4
35/50
4
35/50
4
Start-up current
- without start-up current limiter
- with start-up current limiter
A
A
58
< 45
76
< 45
97
< 45
Rated output
- min. for B-5W35
- max. for B20W60
- Auxiliary heating
kW
kW
kW
1.4
2.8
2/4
1.9
4.0
2/4
2.4
4.9
2/4
EN 60529 level of protection
-
IP 20
Hydraulic connections
- Heating circuit flow and return
- Heat source flow and return
- Cold/hot water
mm
mm
mm
G 1 1/4", Ø 28
G 1 1/4", Ø 28
R 3/4"
Integrated domestic hot water cylinder
- Contents
- max. operating pressure
- max. temperature and heat pump
- max. temp. with heat pump and auxilia-
ry heating
l
MPa (bar)
°C
°C
175
1 (10)
55
75
Heat source circuit (brine circuit)
- Brine type
- max. operating pressure
- min. inlet temperature
- max. inlet temperature
-
MPa (bar)
°C
°C
Ethylene glycol 30 %
0.3 (3)
-10
20
- Nominal flow rate dT 3K
- Residual head dT 3K
- Nominal flow rate dT 4K
- Residual head dT 4K
- Electrical power consumption - pump
l/h
mbar
l/h
mbar
W
1453
335
1090
433
132
1936
277
1452
397
132
2530
216
1898
398
195
CH circuit
- max. operating pressure
- min. flow temperature
- max. flow temperature
MPa (bar)
°C
°C
0.3 (3)
25
62
- Nominal flow rate dT 5K
- Residual head dT 5K
- Nominal flow rate dT 10K
- Residual head dT 10K
- Electrical power consumption - pump
l/h
mbar
l/h
mbar
W
1061
386
517
490
93
1375
324
697
460
93
1803
399
848
580
132
Table 13.1 Technical data