Installation instructions for geoTHERM exclusive VWS 0020051614_00
40
6.6.4 Mixer circuit with buffer cylinder (Hydraulic
plan 8)
The unregulated underfloor heating circuits are operat-
ed by the external heating circuit pump from the buffer
cylinder via a mixer. The flow temperature sensor sits
behind the external pump. The heat pump responds to a
demand for heat from the buffer cylinder.
Furthermore, the heat pump actuates the internal do-
mestic hot water cylinder.
WQ
Fig. 6.11 Hydraulic plan 8
Key to Fig. 6.11
16 Outdoor
sensor
18
VF 2 feed temperature sensor
31
Control valve with position indication
32 Cap
valve
33 Strainer
42a Expansion
relief
valve
42b
Expansion vessel heating circuit
42c
Expansion vessel hot water
43
Safety group for hot water pipe
58
Fill and drain valve
<HK2-P> CH pump
RF1
Return temperature sensor
<SK2-P> Diverter valve cooling mode
VF1 supply
temperature
sensor
VF2 supply
temperature
sensor
WQ Heat
Source
a
Caution!
Error function in cooling mode!
The buffer cylinder must not be in opera-
tion during the cooling mode of the heat
pump.
Insert a motor-powered 3 way valve in
the flow and return respectively, so that
the buffer cylinder is bypassed in the
cooling mode.