Installation instructions for geoTHERM exclusive VWS 0020051614_00
12
3.2 Regulations,
rules,
guidelines
As part of the installation, commissioning and operation
of the heat pump and the DHW storage you must take
into account the current versions of the following regu-
lations or standards, along with any local directives or
guidelines that may apply.
– Electricity at work act.
– Health and safety at work act
– Relevant Utility supplier’s regulations.
– Water regulations and by-laws.
– Environment agency and local council requirements
regarding bore holes, water courses, or noise levels.
– Gas safety installation and use regulations concerning
any associated gas fired heat source used within the
heating system.
– Building regulations part “L” and directives concern-
ing energy saving
– Building regulations such as G3 covering Hygiene and
L8 Legieonella.
– COSHH regulations
– Other relevant bodies such as HETAS and OFTEC
3.3 Coolants
The heat pump is delivered with an operational filling of
R 407 C coolant. This is a chlorine-free coolant which
does not affect the Earth's ozone layer. R 407 C is nei-
ther a fire hazard nor an explosion risk.
However, maintenance work and interventions into the
coolant circuit may only be undertaken by an expert
technician with appropriate protective equipment.
d
Danger!
R 407 C coolant!
Do not inhale gases or vapours emanat-
ing from leaks in the coolant circuit.
Risk to health! Avoid contact with the
skin and eyes. Escaping coolant can
cause freezing if the exit point is
touched! R 407 C coolant presents no
danger in normal use and under normal
conditions. With improper use, however,
it can cause injury and damage.
a
Caution!
This appliance contains R 407 C coolant.
The coolant must not be allowed to es-
cape into the atmosphere. R 407 C is a
fluorinated greenhouse gas covered by
the Kyoto Protocol, with a GWP of 1653
(GWP = Global Warming Potential).
Before the appliance is disposed of, the
coolant it contains must be completely
drained into a suitable vessel so that it
can then be recycled or disposed of in
accordance with the regulations.
The relevant work in connection with the
coolant may only be carried out by offi-
cially certified specialists.
Draining or filling with new coolant (see
identification plate for quantity) may
only be carried out via the service
valves. All warranties become void if any
approved replacement coolant other
than the R 407 C recommended by Vail-
lant is used.
a
Danger!
Danger of lack of tightness by using po-
tassium carbonate as brine lotion!
Insertion of potassium carbonate/water
as brine lotion is not allowed because it
can amount to interactions with the in-
stalled seal synthetic materials in the
brine mixing valve.