Installation instructions for geoTHERM exclusive VWS 0020051614_00
10
2.4
General notes on operating modes and func-
tions
There are five operating modes available for the heating
circuit and these can be used for time and temperature
control of the heat pump (see Chap. 8 "Control sys-
tem").
There are a further three operating modes available for
the integrated domestic hot water cylinder.
During start-up, you will tell the heat pump which of the
connection configurations listed in the appendix corre-
sponds to your installation by entering the number of
the corresponding hydraulic plan into the controller.
Thus all the operating parameters will be set to prede-
termined values, so that the heat pump can work opti-
mally. However, you can individually set and adapt the
operating modes and functions afterwards.
You will find all the information on operating modes,
auxiliary and special functions in Chapter 8, "Control
system".
The heat pump is equipped with numerous
automatic
auxiliary functions
to ensure trouble-free operation
(see also Chap. 8.2 "Automatic auxiliary functions"):
–
Frost protection
Prevents the heating system from freezing
–
Tank frost protection
Prevents the connected tanks from freezing
–
Checking the external sensors
Checking the connected sensors during initial commis-
sioning using the basic hydraulic circuit that was en-
tered previously
–
Protection against loss of heating water
Shuts down when there is a loss of heating water and
switches on again when there is sufficient water pres-
sure
-
Protection against loss of brine
Shuts down if the brine pressure is too low and
switches on again when the pressure is sufficient
–
Floor protection circuit
Overheating protection for the floor (important for
wooden floors)
–
Pump blocking protection
Prevents seizing of pumps in the system
-
Freeze protection function
Shuts down the compressor if the temperature of the
heat source falls below a predetermined value
Additionally, there are further
settable auxiliary func-
tions
available (see also Chap. 8.3 "Settable auxiliary
functions"):
–
Timer programmes
To set the heating times for each heating circuit
–
Holiday programming
Programming of two holiday periods with date entry
and set-back temperature
–
Party function
Carries the heating and hot water times forward to
the next shut-off point
–
Energy saving function
Lowers the flow setpoint temperature for a adjustable
period
–
Screed floor drying
For drying out screed floors
–
Fixed value controlling
Sets a fixed flow temperature
–
Anti-Legionella function
Kills germs in the tank and in the pipes
–
Quick test
Test function for maintenance
–
Remote maintenance
Diagnostics and setting via vrDIALOG or
vrnetDIALOG
–
Cooling function
Cooling of the living rooms during the summer opera-
tion
2 Description of the appliance