Installation instructions for geoTHERM exclusive VWS 0020051614_00
32
6.2
Regulations pertaining to electrical installa-
tions
The maximum sensor cable length of 50 m may not be
exceeded.
Where lengths are greater than 10m, route the connec-
tion cables carrying 230V separately from the sensor or
bus cables.
Do not use free terminals on the appliance as support
terminals for other wiring.
6.3 Electrical
control
box
1LL
L
L
L
1
L
NNNN
N
2
N2
1L
N
23
4
5
SCH
6
7
8
ASB
1
2
3
4
5
6
10
12
11
7
9
8
Fig. 6.1 Electrical control box
Key to Fig. 6.1
1 Cable
clamps
2 Connector block for sensors and external components
3 Control circuit board (below the cover plate)
4 Electric power supply for heat pump (unblocked mains supply)
5 Electric power supply for electric auxiliary heating and control
(dual-circuit supply)
6 Connection terminal for initial current limiter
7 Initial current limiter circuit board
8 Starting capacitor (compressor)
9 Operating capacitor for compressor
10 Safety thermostat (STL) for the auxiliary heating
11 Contactor for auxiliary heating rod
12 Contactor for compressor
Additionally, there are two coiled cables hanging inside
the control box (not shown here):
– small two-way plug:
connecting cable for the operating console
– large three-way plug:
power supply for vrnetDIALOG
A control cable for the vrnetDIALOG is also supplied (ac-
cessories).
6.4
Connecting the power supply
Different types of power supply are provided for heat
pumps by the power companies. The heat pump can be
operated with various types of mains feed. Three types
of connection are described on the following pages.
• Pass the power supply lines(s) through the left handle
trough in the rear panel of the unit
• Pass the lines through the wiring circuit in the domes-
tic hot water cylinder insulation (see Fig. 2.7, item
1
)
downward to the electric control box, through appro-
priate cord grips and to the connection terminals of
the terminal block.
• Carry out the wiring of the connection as illustrated in
the following wiring diagrams.
a
Caution!
The appliance covers must be fitted
after completion of the installation work.
6 Electrical installation
Summary of Contents for geoTHERM exclusive
Page 91: ......