vacon • 67
Parameters
6
6.1.1
Column explanations
Code
=
Location indication on the keypad; Shows the operator the parameter num-
ber.
Parameter= Name of parameter
Min
=
Minimum value of parameter
Max
=
Maximum value of parameter
Unit
=
Unit of parameter value; Given if available
Default
=
Value preset by factory
ID
=
ID number of the parameter
Description= Short description of parameter values or its function
=
More information on this parameter available; Click the parameter name
6.1.2
Group 3.1: Motor settings
6.1.2.1
Group 3.1.1: Motor nameplate
6.1.2.2
Group 3.1.2: Motor Control
Table 45. Motor nameplate parameters
Code
Parameter
Min
Max
Unit
Default
ID
Description
P3.1.1.1
Motor Nom Voltg
Varies
Varies
V
Varies
110
Find this value Un on the
rating plate of the motor.
Note also used connection
(Delta/Star).
P3.1.1.2
Motor Nom Freq
8.00
320.00
Hz
Varies
111
Find this value fn on the rat-
ing plate of the motor.
P3.1.1.3
Motor Nom Speed
24
19200
rpm
Varies
112
Find this value nn on the rat-
ing plate of the motor.
P3.1.1.4
Motor Nom Currnt
Varies
Varies
A
Varies
113
Find this value In on the rat-
ing plate of the motor.
P3.1.1.5
Motor Cos Phi
0.30
1.00
0.74
120
Find this value on the rating
plate of the motor
P3.1.1.6
Motor Nom Power
Varies
Varies
kW
Varies
116
Find this value In on the rat-
ing plate of the motor.
Table 46. Motor control
Code
Parameter
Min
Max
Unit
Default
ID
Description
P3.1.2.1
0
1
0
600
0 = U/f Freq ctrl open loop
1 = Speed control open loop
P3.1.2.2
0
1
0
650
0 = Induction motor
1 = PM motor
Summary of Contents for 100X series
Page 1: ...vacon 100 x ac drives Solar pump application manual ...
Page 2: ......
Page 6: ...vacon 3 Vacon 100X Solar Pump Application 1 ...
Page 8: ...2 vacon 5 Safety ...
Page 160: ...vacon 157 Parameters 6 ...
Page 169: ...Fault vacon 166 Service support find your nearest Vacon service center at www vacon com 7 ...
Page 170: ...7 vacon 167 Fault ...
Page 171: ......