37
8-3. Safety Stop
The Z1 features a Safety Stop function.
After a dive of 10m/33ft or deeper, when ascending without a decompres-
sion stop, a 3-minute countdown timer will activate at a depth of 6m/20ft.
This timer will continue to run from a depth of 6m/20ft and will stay on until
you reach a depth of 1.6m/5ft. It is highly recommended that you not ascend
to the surface without first stopping at approximately 6m/20ft until the
3-minute timer completes its count-down.
1. At the depth of 6m/20ft, the Safety Stop alarm “pi” comes on and STOP
is displayed.
2. The countdown timer displays (03:00), and the 3-minutes timer starts
its countdown.
3. After 3 minutes, [
↑
OK] is displayed for 5 seconds. At this point you
can fi nish your ascent to the surface.
Operational changes at depth during a Safety Stop.
Water depth
Count-down function
display
1.5m/5ft or shallower
end (reset)
Surface Mode
1.5m/5ft~6m/20ft
normal function
Safety stop
6m/20ft~10m/33ft
stop (data is saved)
Dive Mode
10m/33ft or deeper
end (reset)
Dive Mode
NOTES:
The Safety Stop function terminates 1 of 3 ways:
1. When the 3-minute countdown timer zeros out.
2. When you ascend to less than 1.6m/5ft from the surface.
3. When you descend to 10m/33ft or deeper.