ChefTop
™
English
Power cable replacement
The cable must only be replaced by authorised personnel.
The earthing cable must be yellow and green. To replace the power supply cable (if using a terminal board
with a pre-installed cable), proceed as follows:
•
Open the terminal board cover by removing the fixing screws
•
Connect the wires in accordance with the selected connection diagram
•
Secure the cable using the relevant cable clamp
•
Close the terminal board cover and tighten the fixing screws
Caution!
The power supply cable may only be replaced by the manufacturer, a representative from the Assistance
Service or a similarly qualified member of staff.
Incorrect connection may cause the terminal board to overheat so much that it melts. In light of the
above information, UNOX accepts no responsibility for any situation resulting from work carried out in
an unprofessional manner, or from the incorrect intepretation or application of regulations. The appliance
must be connected to the electricity mains earth conductor.
Equipotential connection
The appliance must be included in an equipotential system, which has been checked for efficiency in accordance
with the specifications set out in current regulations.
This connection must be performed between different appliances, using the terminal marked as equipotential.
The equipotential wire must have a minimum cross-section of 10 mm and must be yellow and green.
Electrical connections
29