11.TIMING CHART
42
11-3-4. About the stop signal
When the STOP signal is turned ON, all the signals of the SP1 output, SP2 output and SP3 output are
turned OFF.
If the START signal is turned ON when the STOP signal is ON, a sequence error will result.
For resetting the sequence error, input the stop signal again.
11-3-5. Relationship between AZ times, judging times, and
automatic fall compensation
【
Example: AZ times=3, JUDGING times=2, AVG.CNT of AFFC=2
】
When the number of AZ times is set at 01, tare subtraction is performed at each time when weighing is
started.
When the number of AZ times is set at 02 to 99, tare subtraction is performed at the intervals of these
times.
When the number of AZ times is set at 00, the AZ function is turned OFF.
When the number of judging times is set at 01, judgment is made at each time when weighing is
finished.
When the number of judging times is set at 02 to 99, judgment is made at the intervals of these times.
When the number of judging times is set at 00, overweight/underweight comparisons are not made.
Since weighed values for automatic fall compensation are sampled at the time of judgment, the
automatic fall compensation does not function when no judgment is made.
ON
OFF
ON
ON
ON
ON
START input
STOP input
SP1 output
SP2 output
SP3 output
ERR output
START
AZ times
3 times
TARE ON
END
Judgment
Fall compensation
Judging times
2 times
Average count of automatic
2 times