4.CALIBRATION
19
4-3-6. Span calibration
Set the actual load value under an actual load.
Setting range:
00001 to 99999 (The decimal point is selectable.)
4-4. Net Over/ Gross Over
When the net weight value or gross weight value exceeds a fixed regulation, an alarm is given by this
function.
NET OVER:
00000 to 99999
GROSS OVER:
00000 to 99999
The alarm is given when the following conditions are met.
4-5. Unit Setting
Set the unit of the load to be displayed.
The display value (calibration value) is not affected by changing the unit.
Alternatives:
[
NONE
]
[
kg
]
[
t
]
[
g
]
[
N
]
[
lb
]
4-6. Tare Subtraction
The net weight is zeroed by this function. The gross weight value is not
changed by this operation.
Alternatives:
[
RESET
]
[
NO
]
[
YES
]
: Perform the tare subtraction.
:
Go back to the previous screen without executing tare subtraction.
:
Reset the tare subtraction
.
MODE
[
CALIBRATION
]
[
SPAN CAL.
]
→
→
Once
→
MODE
Once
[
CALIBRATION
]
[
NET OVER
]
→
→
→
Once
→
MODE
Once
[
CALIBRATION
]
[
GROSS OVER
]
→
→
→
Once
→
Conditional expression
Display
NET OVER
Net weight
>
“NET OVER” set value
NET OVER
GROSS OVER
Gross weight
>
“GROSS OVER” set value
GROSS OVER
MODE
Once
[
CALIBRATION
]
[
UNIT DISPLAY
]
→
→
→
Once
→
TARE
ON
* It operates it with the net weight (NET) displayed.
YES
NO
RESET