14.RS-232C INTERFACE
48
-
Status read (7-digit)
-
Status read (7-digit)
-
Parameter read (example: High limit)
-
Parameter write (example: High limit)
* When you write in a setup which it is not with the sign, put “0” in the sign digit.
* Please refer to "21 SETTING ITEM LIST" on page 65 for command No. and the number of
set digits.
- Parameter code read
-
Parameter code write
HI-HI limit
HI limit
Proper weight
Near zero
LO-LO limit
LO limit
Host
F600AT
R
F
R
F
0
0
0
0
0
0
0
Terminator
CR
1: ON
0: OFF
1: ON
0: OFF
1: ON
0: OFF
1: ON
0: OFF
1: ON
0: OFF
1: ON
0: OFF
Sequence error
(0 to 5)
+LOAD occurred
-LOAD occurred
GROSS OVER occurred
NET OVER occurred
No error
Host
F600AT
R
G
R
G
0
0
0
0
0
0
0
Terminator
CR
: 4
: 3
: 5
: 4
: 2
: 1
: 3
: 1
: 0
: 1
: 0
Weight error
No Weight error
In equivalent input calibration
In span calibration
In zero calibration
In weighing
Host
F600AT
W
0
W
0
2
±
1
0
0
0
CR
0
Terminator
2
Command No.
Parameter No.
5-digit parameter (no decimal point)
Sign
Host
F600AT
W
0
2
±
1
0
0
0
0
CR
Command No.
5-digit parameter (no decimal point)
Sign
Host
F600AT
W
0
W
0
0
0
0
0
0
0
CR
0
Parameter code 0 to 7
Terminator
Host
F600AT
W
0
0
0
0
0
0
0
CR
Parameter code 0 to 7