RF POWER SUPPLY and MATCHINGBOX
4. Functions
56
M = 2 0 0 0 / 3 0 0 0 G
1 0
Z = 2 0 0 0 / 1 4 7 5 G
1 0
T = 5 0
O = 2 0 0 0 / 1 4 7 5 G
1 0
M = 6 0
r =
0 W
A U T O
P R G = 0
Figure 4-33 Impedance sensor screen (P19)
Item
Parameter details
M
Impedance sensor value M: motor value/threshold/gain
Z
Impedance sensor value Z: motor value/threshold/gain
O
Impedance sensor value O: motor value/threshold/gain
r
Displays the reflected wave power
T
Displays TUNE current value
M
Displays MATCH current value
AMC
Select matching mode
AUTO: Set auto matching
MANU: Set manual matching
PRG
Selects the program number or displays the current value.