![Ulvac RFP-N Instruction Manual Download Page 91](http://html1.mh-extra.com/html/ulvac/rfp-n/rfp-n_instruction-manual_4491971091.webp)
RF POWER SUPPLY and MATCHINGBOX
6. Matching Adjustment
83
Table 6-25 MBX-1350N - 5 taps
00%
10%
20%
30%
40%
50%
60%
70%
80%
90%
99%
99%
5000
5000
5000
5000
5000
5000
3950
2350
1450
900
600
90%
5000
5000
5000
5000
5000
5000
3950
2350
1450
900
600
80%
5000
5000
5000
5000
5000
5000
3950
2350
1450
900
600
70%
5000
5000
5000
5000
5000
5000
3950
2350
1450
900
600
60%
5000
5000
5000
5000
5000
5000
3950
2350
1450
900
600
50%
5000
5000
5000
5000
5000
5000
3950
2350
1450
900
600
40%
5000
5000
5000
5000
5000
5000
3950
2350
1450
900
600
30%
5000
5000
5000
5000
5000
5000
3950
2350
1450
900
600
20%
5000
5000
5000
5000
5000
5000
3950
2350
1450
900
600
10%
5000
5000
5000
5000
5000
5000
3950
2350
1450
900
600
00%
5000
5000
5000
5000
5000
5000
3500
2300
1450
900
600
TUNE
M
A
T
CH
MBX-1350N-(5T)
Table 6-26 MBX-1350N - 6 taps
00%
10%
20%
30%
40%
50%
60%
70%
80%
90%
99%
99%
5000
5000
5000
5000
4000
2100
1200
650
400
150
50
90%
5000
5000
5000
5000
4200
2200
1200
650
400
150
50
80%
5000
5000
5000
5000
4400
2250
1200
650
400
150
50
70%
5000
5000
5000
5000
4400
2250
1200
650
400
150
50
60%
5000
5000
5000
5000
4400
2250
1200
650
400
150
50
50%
5000
5000
5000
5000
4400
2250
1200
650
400
150
50
40%
5000
5000
5000
5000
4400
2250
1200
650
400
150
50
30%
5000
5000
5000
5000
4400
2250
1200
650
400
150
50
20%
5000
5000
5000
5000
4400
2250
1200
650
400
150
50
10%
5000
5000
5000
5000
4400
2250
1200
650
400
150
50
00%
5000
5000
5000
5000
4400
2250
1200
650
400
150
50
TUNE
M
A
T
CH
MBX-1350N-(6T)
* When making adjustments such as adding a fixed capacitor, the deratings will differ from the above
derating table.