YK11-0016-DI-002-08
33
WARNING
Turn OFF the Power Supply to do the electrical connection.
Never try to work on it on keeping the electricity turned ON.
A correct wiring work must observe the law and the rule that relates
safely. A wrong wiring work might start a fire.
The measures such as lockout/tag out should be executed not so as
to turn the power switch by mistakes during working.
You have a risk of getting electrical shock when the machine caused
a failure or electrical leakage.
Make sure to have the steady grounding.
You are also recommended to install a dedicated earth leakage breaker.
The screw of the earth terminal at the motor side is provided with an
“earth mark
” in the terminal box.
The diameter of the cable to connect to a ground is the same as a
cable supplying a power supply in a motor at least.
Be sure to ground the motor ground terminal
200V - 240V: Ground to 100ohm or less
380V - 460V: Ground to 10 ohm or less
Use a safety circuit which keeps the motor from starting a fire which
is caused by over current.
Install a safety circuit suitable for the capacity of the motor. If a safety
circuit is not installed, or if a safety circuit that is unsuitable for the
motor capacity is installed, the motor will be damaged leading to fire.
The safety circuit must use the one that operates by the ratings
current value of the motor that uses it.
Do the setting of the safety circuit in a rating current value of the motor
in line with the voltage and the frequency of the power supply.
When a motor is different from the standard, please do the setting of
the safety circuit in a rating current value of the motor you use.
Never fail to close the Terminal box cover to operate the Pump.
Do not use it excluding the voltage rating of the motor. It causes
damaging by a fire and a fire of the motor.
Multi rated Motor
The connector in the terminal box, with 380V-460V and 200V-240V
power supply voltage, please change the wiring.
CAUTION
Do the Direct-in start connection.
Summary of Contents for PMB100D
Page 2: ......
Page 3: ...Declaration of Conformity...
Page 39: ...YK11 0016 DI 002 08 12 2 4 Dimensional drawing Fig 11 Dimensional drawing PMB100D...
Page 40: ...YK11 0016 DI 002 08 13 Fig 12 Dimensional drawing PMB300D...
Page 41: ...YK11 0016 DI 002 08 14 Fig 13 Dimensional drawing PMB600D...
Page 42: ...YK11 0016 DI 002 08 15 Fig 14 Dimensional drawing PMB1200D...
Page 43: ...YK11 0016 DI 002 08 16 Fig 15 Dimensional drawing PMB2400D...
Page 62: ...YK11 0016 DI 002 08 35...
Page 65: ...YK11 0016 DI 002 08 38...
Page 72: ...YK11 0016 DI 002 08 45...
Page 84: ...YK11 0016 DI 002 08 57 Fig 28 PMB300D Optional attachment figure...
Page 85: ...YK11 0016 DI 002 08 58 Fig 29 PMB600D Optional attachment figure...
Page 86: ...YK11 0016 DI 002 08 59 Fig 30 PMB1200D Optional attachment figure...
Page 89: ...YK11 0016 DI 002 08 62 Fig 33 Dimensional drawing PMB2400D Horizontal exhaust model...
Page 99: ...YK11 0016 DI 002 08 72...
Page 105: ...YK11 0016 DI 002 08 78...
Page 119: ......