![Ulvac PMB100D Instruction Manual Download Page 68](http://html1.mh-extra.com/html/ulvac/pmb100d/pmb100d_instruction-manual_4492079068.webp)
YK11-0016-DI-002-08
41
4. Operation
4.1 Caution on Operation
WARNING
Never run the Vacuum pump on blocking up the exhaust outlet,
putting any device that hampers the gas passage. There is a risk that
pressure in the pump rises, and the main body of the pump and the
oil level gauge might explode, or the motor become an overload.
This product is not made as the withstand pressure structure.
Ensured pressure value of the Pump shall be 0.03MPa (0.3kgf/cm2)
(Gauge pressure).
If any valve was put to a pipe after the Exhaust outlet, check and
ensure that it is open.
CAUTION
Ensure to flow the cooling water during operation. Required Cooling
water shall be;
Cooling water volume:
PMB100D : air cooling
PMB300D : 2 L/min or more
PMB600D : 2 L/min or more
PMB1200D : 3 L/min or more
PMB2400D : 3 L/min or more
Cooling water temperature: 5°C ~ 30°C
Shortage of the cooling water might give damage on the bearing, gear
and shaft sealing, which results in contact of the rotor and casing and
operation stop.
CAUTION
Never fail to lubricate the machine.
If the lubrication oil came down lower than limit level during
operation, it might give damage on the bearing, gear and rod sealing
and result in leak, noise, motor overload and operation stop.
Never fail to conduct the lubrication oil out gassing before starting
operation when lubricated a new the Mechanical booster pump or left
it a long time after lubrication.
Starting operation without out gassing might generate a lot of
bubbles and cause them flow in the Rotor chamber.
CAUTION
Metal noise of high frequency might arise from the Mechanical seal
section during operation. That noise is indicating the oil shortage in
the Mechanical seal section.
In such a case, stop running the Pump and lubricate it following the
description of the “3.6.2 Lubrication to the Mechanical seal” and
restart operation after several minutes.
Summary of Contents for PMB100D
Page 2: ......
Page 3: ...Declaration of Conformity...
Page 39: ...YK11 0016 DI 002 08 12 2 4 Dimensional drawing Fig 11 Dimensional drawing PMB100D...
Page 40: ...YK11 0016 DI 002 08 13 Fig 12 Dimensional drawing PMB300D...
Page 41: ...YK11 0016 DI 002 08 14 Fig 13 Dimensional drawing PMB600D...
Page 42: ...YK11 0016 DI 002 08 15 Fig 14 Dimensional drawing PMB1200D...
Page 43: ...YK11 0016 DI 002 08 16 Fig 15 Dimensional drawing PMB2400D...
Page 62: ...YK11 0016 DI 002 08 35...
Page 65: ...YK11 0016 DI 002 08 38...
Page 72: ...YK11 0016 DI 002 08 45...
Page 84: ...YK11 0016 DI 002 08 57 Fig 28 PMB300D Optional attachment figure...
Page 85: ...YK11 0016 DI 002 08 58 Fig 29 PMB600D Optional attachment figure...
Page 86: ...YK11 0016 DI 002 08 59 Fig 30 PMB1200D Optional attachment figure...
Page 89: ...YK11 0016 DI 002 08 62 Fig 33 Dimensional drawing PMB2400D Horizontal exhaust model...
Page 99: ...YK11 0016 DI 002 08 72...
Page 105: ...YK11 0016 DI 002 08 78...
Page 119: ......